Controlling Another Device with the AR-3000R
 
Applications
 
AR-3000R Settings
 
The setting for the Busy Out signal is a system-wide setting 
(that is, it is not made separately for individual phrases).
The setting for whether the Busy Out signal is output is made 
separately in the following three situations. Choose the one 
that matches your usage conditions.
ON/OFF
• During phrase playback: in Phrase Play ON/OFF
Repeat Int ON/OFF
 
fig.15-02e (Busy Out)
 
Inserting into a phrase a delay time equal to the start time for 
the amp (the time until sound is played) can help prevent 
drop-out at the beginning of the phrase during playback.
 
Procedure for Making the Setting for Busy Out 
Signal Output
 
1.
 
Press the MODE button.
The MODE indicator lights up.
 
2.
 
Use the SELECT dial to choose “9.5 Busy Out,” then 
press the dial.
 
3.
 
Turn the SELECT dial to choose “in Delay Time (OFF or 
ON),” then press the dial.
 
fig.15-g01e
 
4.
 
Turn the SELECT dial to choose “in Phrase Play (OFF or 
ON),” then press the dial.
 
5.
 
Turn the SELECT dial to choose “in Repeat Interval (OFF 
or ON),” then press the dial.
 
6.
 
When the prompt appears on the screen, press the 
ENTER button to enable the settings.
To quit, use the SELECT dial to choose “NO,” then press the 
ENTER button.
When you’re finished making the setting, the display returns 
to the setting item selection screen.
 
7.
 
Press the MODE button.
This ends the setting process and returns you to the usual 
screen.
 
* While making the settings, you can go back to the previous 
entry position (highlighted) by using the PAUSE (BACK) 
button.
* If you press the MODE button while making settings, a 
message asking you to confirm that you want to exit the 
setting process appears. Note that if you choose “YES,” then 
press the ENTER button, you are returned to the usual screen, 
and all setting changes you’ve made up to that point will be 
discarded.
During Repeat interval
During Delay time
During Phrase
playback
AUDIO OUTPUT
Busy Out
Make start
Make finish
Close (ON)
Open (OFF)
ON : ON : ON
ON : ON : OFF
ON : OFF : ON
ON : OFF : OFF
OFF : ON : ON
OFF : ON : OFF
OFF : OFF : ON
OFF : OFF : OFF
Repeat Int 
Delay Time
Phrase Play