Controlling the AR-3000R Using MIDI Signals (MIDI Control)
 
Procedure for Setting the MTC Error Level
 
1.
 
Press the MODE button.
The MODE indicator lights up.
 
2.
 
Use the SELECT dial to choose “6.9 MTC,” then press the 
dial.
 
3.
 
Press the SELECT dial to advance the input location 
(highlighted) to “MTC Error Level.”
 
4.
 
Turn the SELECT dial to choose the MTC Error Level 
(from 0 to 10), then press the dial.
 
fig.16-g18e
 
5.
 
When the prompt appears on the screen, press the 
ENTER button to enable the settings.
To quit without making the settings, use the SELECT dial to 
choose “NO,” then press the ENTER button.
Once the settings have been successfully modified, you’re 
returned to the setting item selection screen.
 
6.
 
Press the MODE button.
This ends the setting process and returns you to the usual 
screen.
 
* While making the settings, you can go back to the previous 
entry position (highlighted) by using the PAUSE (BACK) 
button.
* If you press the MODE button while making settings, a 
message asking you to confirm that you want to exit the setting 
process appears. Note that if you choose “YES,” then press the 
ENTER button, you are returned to the usual screen, and all 
setting changes you’ve made up to that point will be discarded.
 
Operation Procedures
 
When you have finished making the settings, carry out 
playback on the connected master device. Phrase playback in 
sync with received MIDI time codes starts.
When Sync Source is set to MTC, the indicators on the front 
panel of the unit light up as shown below.
 
fig.16-08e
 
• Playback is paused when MTC (Full messages; p. 139) is 
received, or the PLAY button is pressed.
• To enter recording standby under the control of MTC, 
press the PLAY button while holding down the STOP 
button, then press the PAUSE button again.
A screen like the following appears during playback.
 
fig.16-08ae
 
Note that there is no operation unless MIDI time codes are 
input from the external MIDI instrument.
 
AR-3000R Settings (When the 
AR-3000R Is the Master)
 
Selection of MIDI Output (MIDI OUT or 
MIDI THRU)
 
This switches the functioning of the MIDI output connector. 
Here, select “OUT.”
 
OUT:
 
 This sends MIDI information from the unit. Select this 
when you want to play back MIDI phrases, send Exclusive 
(SysEx) messages, or make the AR-3000R the master during 
synchronization using MIDI signals.
 
THRU:
 
 This takes MIDI information from MIDI IN and sends 
it out unchanged. MIDI information from the AR-3000R itself 
is not output.
 
Procedure for Setting MIDI Output (MIDI OUT 
or MIDI THRU)
 
PLAY button
PAUSE button
During Pause
During Rec standby
Lights in green
Lights in red
Lights in orange
Lights in orange
Remaining time for phrase playback
MIDI Time Code