124
Synchronized Recording and Playback with Multiple AR Units
 
Unit Settings
 
Setting the AR-LINK Mode
 
OFF:
 
 There is no synchronization using AR-LINK. Even 
when this is set to Off, signals input to AR-LINK IN are 
output from AR-LINK OUT.
 
MASTER:
 
 This enables operation as the AR-LINK master.
 
SLAVE:
 
 This enables operation as the AR-LINK slave. Use 
this settings for the second and later AR units connected 
using AR-LINK.
 
Procedure for Setting the AR-LINK Mode
 
1.
 
Press the MODE button.
The MODE indicator lights up.
 
2.
 
Use the SELECT dial to choose “8.1 AR-LINK Mode,” 
then press the dial.
 
3.
 
Turn the SELECT dial to choose the AR-LINK Mode 
(OFF, MASTER, or SLAVE), then press the dial.
 
fig.19-g02e
 
4.
 
When the prompt appears on the screen, press the 
ENTER button to enable the settings.
To quit without making the settings, use the SELECT dial to 
choose “NO,” then press the ENTER button.
Once the settings have been successfully modified, you’re 
returned to the setting item selection screen.
 
5.
 
Press the MODE button.
This ends the setting process and returns you to the usual 
screen.
 
* If you press the MODE button while making settings, a 
message asking you to confirm that you want to exit the 
setting process appears. Note that if you choose “YES,” then 
press the ENTER button, you are returned to the usual screen, 
and all setting changes you’ve made up to that point will be 
discarded.
 
Recording Procedure
 
For the master, these are the same as the usual recording 
procedure (p. 41) and recording settings (p. 42). The slave AR 
units operate according to the operation of the master.
 
fig.19-g03e
 
* When you set the master, all slave AR units connected by AR-
LINK are set to the same value.
* During recording, you can stop the slave AR units 
individually, by operating their respective panels.
 
Playback Procedure
 
For the master, this is the same as the usual playing back 
procedure. The slave AR units operate according to the 
operation of the master.
 
fig.19-g04e
 
* During playback, you can stop the slave AR units 
individually, by operating their respective panels.
* If independent playback is carried out on the slave AR-3000R, 
the indication for the fact that it is an AR-LINK slave 
disappears.
 
Phrases used for synchronized AR-LINK playback must all 
be the same Card Slot, REC Type, RDAC-Grade, and RDAC-
Mode. If a card having a different setting than the master is 
inserted into an AR unit, the AR unit will not operate. In 
such instances, connected slave AR units thereafter are not 
affected.
 
Please be aware that a second or subsequent AR unit 
connected through AR-LINK cannot be set as the master.
 
AR-LINK signals are not sent from the master in cases like 
the ones below.
• When the Dual Mono mode is “ON”
• When the master is playing back a MIDI phrase, song 
phrase, or pattern phrase
AR-LINK Master
AR-LINK Slave
REC Standby
(Slave)
During recording
(Slave)
During playback
(Master)