Appendices
 
Terminals
 
Specifications of the Control 
 
Input/Output Terminals
 
fig.21-02e
 
1. Control Input
 
Trigger Signal Format:  On, Off (Open, Close), Pulse width: 
20 msec or more
Contact capacity: DC 24 V, 0.1 A or more
Input: Photocoupler
Pins used for control input:
• Direct playback:  1–16, STOP, COM
• Program playback: START, STOP, INC, DEC, 
EXCHANGE, COM
• Binary playback: 1–10, 11, START, STOP, COM
• Control-port recording : 1–10, 11, 13, 14, COM
 
* Time from make-contact onset until playback starts is 
approximately 40 ms (typ.). However, please be aware that this 
may vary slightly depending on card type.
* During binary playback, complete input specifying binary 
signals within 50 ms.
* The two common (COM) connectors are connected internally, 
so you can achieve operation by making the connection to 
either one. In cases such as when you are connecting the 
control connectors of a number of AR units with a single 
make-contact point, connect one COM connector on each AR 
unit to each other. However, do not intermix this unit with 
other AR series devices. Doing so may result in unstable 
operation.
 
2. Control Output
 
Signal system: No-voltage make-contact
Contact capacity: DC 30 V, 5 A
Connectors used with control output:
• Busy Out: BUSY OUT
• Control Out: CONT OUT, make-contact time: 1 second
 
3. Audio Output Ports (MONO OUT)
 
MONO OUT is an audio output (mono, unbalanced) ports.
Rated output level: +4 dBu
Output  Impedance: 500 ohm
Recommended Load Impedance: 10 k-ohms or greater
 
* The control I/O connector cannot be used to switch the power 
to the AR unit on or off.
* The output levels may change for stereo and mono audio 
phrases.
 
When making connections to the ports, be careful not to lose 
the removed screws. Place the screws out of the reach of 
small children. If a screw is accidentally swallowed, 
immediately consult a physician.
 
RS-232C Connector 
 
Specifications
 
Transmission method: Start-Stop synchronous system 
(Asynchronous)Duplex data transmission
Baud rate: 4800 /9600/19200/38400 bps
Parity: none
Data length: 8 bit
Stop bit length: 1 bit
Code set: ASCII
 
* The setting “38400” bps is for compatibility with legacy 
models (AR-3000/2000). However, it is a value for the 
communication speed that is not defined by the RS-232C 
standards.
 
fig.21-03e
2
3
1
1
NC
RXD
TXD
DTR
GND
DSR
RTS
CTS
NC
Pin No.
Signal Name
Pin Connection
1
2
3
4
5
6
7
8
9
1
5
6
9
1 : NC
2 : RXD
3 : TXD
4 : DTR
5 : GND
6 : DSR
7 : RTS
8 : CTS
9 : NC
1 : DCD
2 : RXD
3 : TXD
4 : DTR
5 : GND
6 : DSR
7 : RTS
8 : CTS
9 : RI