Exabyte 440 用户手册

下载
页码 208
Chapter 8
128
Exabyte 440 and Exabyte 480
Problems w ith library installation
If your library and application software are not communicating 
after installation, check the following:
Single-ended, low-voltage differential (LVD), and 
high-voltage differential (HVD) devices
. Make sure all 
devices on the bus are all singled-ended or LVD or all HVD. 
You can connect single-ended and LVD devices to the same 
bus. However, mixing the two types of devices results in all 
devices on the bus operating as single-ended devices. These 
devices include the controller cards, cables, and terminators.
Narrow SCSI and wide SCSI
. Make sure all devices within 
the library are either narrow SCSI or wide SCSI. Do not mix 
narrow and wide SCSI devices within the library.
SCSI cable lengths
. Make sure the internal and external SCSI 
cabling does not exceed maximum lengths (see 
).
Termination
. Make sure your bus is properly terminated as 
described in 
. If another SCSI device previously 
terminated the SCSI bus and is no longer at the physical end 
of the bus, be sure to remove the terminators from that device.
SCSI bus connections
. Make sure that all SCSI cables and 
terminators are securely connected to the appropriate SCSI 
connectors on the back of the library. See 
 for more 
information.
SCSI IDs
. Make sure that the SCSI IDs you selected for the 
tape drives and library are not the same as IDs used by any 
other SCSI device on that bus, including the SCSI adapter 
card. The library does not check for duplicate IDs. See 
 
for instructions.