Exabyte 480 用户手册

下载
页码 208
Chapter 4
82
Exabyte 440 and Exabyte 480
Resetting the library
If the library has encountered an error and is still not operating 
after you have tried the corrective action for the error, you may 
need to reset the library. A reset causes the library and the tape 
drives to perform their power-on self tests. Unless configured 
otherwise, tape drives will rewind the tape after a reset, but will 
not eject the data cartridge.
Note:
If the library is performing a cartridge move operation 
when it is reset, it completes the move operation before it 
performs the power-on self-test.
To reset the library, you can use one of the following methods:
 Press >5HVHW@ on the operator panel, then press >(QWHU@ at the 
confirmation screen (or press 
>(VFDSH@ to cancel).
 Perform a power-on reset by powering the library off, then 
back on.
 Perform a remote hardware reset by plugging a cable into the 
remote reset port on the back of the library and press a reset 
button on the cable. (See 
 for more information.)
Note:
The library, tape drives, or the entire SCSI bus can also be 
automatically reset by the host.
When the library is reset, both the library and tape drives perform 
power-on self-tests. Then the Main Screen appears on the LCD.
CAUTION
Before resetting the library, make sure the library 
or tape drives are not communicating across the 
SCSI bus. Resetting the library and tape drives 
may disrupt communications on the SCSI bus.