Alliance Laundry Systems T453I 用户手册

下载
页码 68
Programming the Electronic OPL Control
25
M414462
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Temperature Sensor
To test the temperature sensor, hold COOL DOWN 
pad and press the TEMP pad in the idle mode. This 
will show the temperature detected by the control.
“SH” displays and signal sounds if the temperature 
sensor is shorted or sensor temperature is over 200°F 
(93°C). Press the STOP/RESET pad twice within 3 
seconds and allow the tumbler to cool, then press an 
ON/SELECT pad. If “SH” still displays, call for 
service.
“OP” displays and signal sounds 3 minutes after the 
tumbler is started if the temperature sensor is faulty or 
if a temperature below 24°F (-4.4°C) is detected. If 
dryer temperature is above 24°F (-4.4°C), call for 
service.
NOTE: To display the software revision level, hold 
the AUTO pad and press the TIME pad while the 
control is in idle mode. 
Temperature Adjustment
Selecting a fabric type selects a preset ideal 
temperature for that fabric. Lower temperatures may 
be needed for small loads or when air flow through the 
tumbler is less than ideal due to inadequate make-up 
air or exhaust ducting. 
Whenever the control is on, but not in NO HEAT, 
COOL DOWN or LOAD READY, pressing the TEMP 
pad displays the three digits of the set temperature. 
Use the MORE or LESS pad to increase or decrease 
the temperature. 
Temperature Display (°F/°C)
To select between Fahrenheit and Celsius display, hold 
in the TEMP display pad while pressing the TEMP 
pad.
NOTE: Temperature can be set from 80°F (27°C) 
to 180°F (82°C) in the SPECIAL CYCLE and 
SPECIAL TIME options only.
To include an adjusted temperature in a Custom cycle, 
simply adjust temperature before pressing CUSTOM.
Cylinder Temperature Display
To see the approximate temperature at the exit of the 
cylinder, press and hold the TEMP DISPLAY pad 
(50-170# Models Only).
Table 4 
Temperature 
Selection
Control 
Program 
Temperature
Desired 
Clothes 
Temperature
°F (°C)
°F (°C)
0220S
0270S
0350S
0220S
0270S
0350S
140 (60) 145 (63) 185 (85) 190 (88)
135 (57) 140 (60)
180 (82)
HIGH
130 (54) 135 (57) 170 (77) 175 (79)
125 (52) 130 (54) 160 (71) 165 (74)
120 (49) 125 (52) 155 (68) 160 (71)
125 (52) 130 (54) 160 (71) 165 (74)
120 (49) 125 (52) 155 (68) 160 (71)
MEDIUM
115 (46) 120 (49) 150 (66) 155 (68)
110 (43) 115 (46)
145 (63)
105 (41) 110 (43) 135 (57) 140 (60)
110 (43) 120 (49) 145 (63) 155 (68)
105 (41) 115 (46) 135 (57) 145 (63)
MED LOW
100 (38) 110 (43) 130 (54) 140 (60)
95 (35)
105 (41) 120 (49) 135 (57)
90 (32)
100 (38) 105 (41) 125 (52)
95 (35)
120 (49)
90 (32)
105 (41)
LOW
85 (29)
100 (38)
80 (27)
95 (35)
75 (24)
95 (35)