Haier CGDE450AW 用户手册

下载
页码 80
1.  This appliance must be properly grounded. Electrical shock can result if the 
dryer is not properly grounded. Follow the instructions in this manual for 
proper grounding.
2.  Do not use an extension cord with this dryer. Some extension cords are not 
designed to withstand the amounts of electrical current this dryer utilizes and 
can melt, creating electric shock and/or fire hazard. Locate the dryer within 
reach of the receptacle for the length power cord to be purchased, allowing 
some slack in the cord. Refer to the electrical requirements in this manual for 
the proper power cord to be purchased.
3.  A UL approved strain relief must be installed onto power cord. If the strain 
relief is not attached, the cord can be pulled out of the dryer and can be cut 
by any movement of the cord, resulting in electrical  shock.
4.  Do not use an aluminum wire receptacle with copper-wired power cord 
and plug (or vice versa ). A chemical reaction occurs between copper and 
aluminum and can cause electrical shorts. The proper wiring and receptacle is 
a copper-wired power cord with a copper-wired receptacle.
Note:  Dryers operating on 208 Volt power supply sill have longer drying times 
than operation on 240 Volt power supply.
WARNING:   Improper connection of the equipment grounding conductor can 
result in a risk of electrical shock. Check with a licensed electrician 
if you are in doubt as to whether the appliance is properly 
grounded.
GAS DRYER (GDG450AW)
1.  Gas dryers are equipped with a factory installed three-prong 15 Amps ~120 
Volts (grounding) plug for your protection against shock hazard and should be 
plugged directly into a properly grounded three-prong receptacle. Do not cut 
or remove the grounding prong from this plug.
English