7.2 Exchanging the Ground Glass 
•  By briefly depressing the “PHASE”-button in standby, 
the shutter is positioned to protect the mirror surface 
from damage as far as possible 
➪ 
photo
.
•  Before exchanging the ground glass, switch the 
camera’s main switch off and disconnect the camera 
from the power supply!
•  Remove the lens or the protective cap.
Do not touch the mirror surface!
•  Using the included special forceps, pull the ground glass 
➪ 
photo
 out of the holder by its tongue 
➪ 
photo
.
•  Check that the ground glass to be inserted as well as 
the ground glass frame are completely clean.
•  With the special forceps, push the chosen ground glass 
into the holder as far as it will go. The red marker 
point must be on the left. A ball catch fixes the ground 
glass exactly in the right position.
•  Check that the ground glass is correctly locked in place.
Note: 
Cleaning or exchanging the field lens, see 
Chapter 13 Maintenance, Cleaning the Field Lens.
tongue
ground glass
Camera Body