Kodak C-41RA 用户手册

下载
页码 8
Choosing the Right Chemicals for Your Minilab
Choosing the Right Chemicals for 
Your Minilab
KODAK Publication No. J-36
CAT 849 8800
Major Revision 4-00
Printed in U.S.A.
Consumer Imaging
EASTMAN KODAK COMPANY 
 ROCHESTER, NY 14650
KODAK EKTACOLOR PRIME Developer Replenisher 
LORR
If new EKTACOLOR PRIME SP Developer Replenisher is 
not yet available in your region, use this developer if your 
minilab consistently operates at high utilization, i.e., a
developer tank turnover occurs at least once every two 
weeks.
Available in sizes to prepare 10 litres and 25 gallons (two 
12.5-gallon mixes) of replenisher solution.
KODAK EKTACOLOR PRIME Developer Regenerator 
If new EKTACOLOR PRIME SP Developer Replenisher is 
not yet available in your region, your can use this regenerator 
to regenerate and reuse EKTACOLOR PRIME
Developer overflow.
Available in sizes to prepare 10 litres and 25 gallons of 
replenisher solution from developer overflow
.
KODAK EKTACOLOR RA Developer Replenisher RT
If your minilab takes longer than four weeks for a tank 
turnover, use this developer.
Available in sizes to prepare 5 and 10 litres and 25 gallons.
KODAK EKTACOLOR RA Developer Starter
To make developer tank solutions, mix this starter with 
KODAK EKTACOLOR PRIME SP Developer Replenisher, 
EKTACOLOR PRIME Developer Replenisher, 
EKTACOLOR PRIME Developer Replenisher LORR, or 
EKTACOLOR RA Developer Replenisher RT according to 
the directions on the starter label.
KODAK EKTACOLOR PRIME Bleach-Fix Replenisher
Use this bleach-fix if you use EKTACOLOR PRIME SP or 
PRIME Developer Replenisher. The replenishment rate with 
this bleach-fix is 50 percent lower than the rate for 
EKTACOLOR RA Bleach-Fix and Replenisher.
Available in sizes to prepare 10 litres and 12.5 gallons of 
solution.
KODAK EKTACOLOR RA 100 Bleach-Fix and 
Replenisher
You can use this bleach-fix if your processor has a tank 
turnover at least every four weeks. The replenishment rate is 
75 percent lower than that of EKTACOLOR RA Bleach-Fix. 
This product will be renamed KODAK EKTACOLOR 
PRIME Bleach-Fix Replenisher LORR.
Available in sizes to prepare 5 litres and 5 gallons of solution.
KODAK EKTACOLOR RA Bleach-Fix and Replenisher
If it takes more than four weeks to turn over the bleach-fix tank 
solution, use this replenisher. Dilute this concentrate to 
prepare a tank or replenisher solution.
Available in sizes to prepare 5 and 10 litres and 25 gallons of 
solution.
KODAK EKTACOLOR PRIME Stabilizer and 
Replenisher
Use this stabilizer in place of a final wash in washless 
minilabs.
Available in sizes to prepare 5 and 10 litres and 
12.5 gallons of solution.
MORE INFORMATION
For the latest version of technical support publications for 
KODAK  Products, visit Kodak on-line at:
  http://www.kodak.com
The Material Safety Data Sheets for these products are 
available on the Kodak web site: 
www.kodak.com/go/MSDS
Many technical support publications for 
KODAK Products can be sent to your fax machine 
from the Kodak Information Center. Call:
U.S. 1-800-242-2424, Ext. 33 / Canada 1-800-295-5531
—Available 24 hours a day, 7 days a week—
If you have questions about KODAK  Products, call Kodak.
In the U.S.A.: 
1-800-242-2424, Monday–Friday
9 a.m.–7 p.m. (Eastern time)
In Canada: 
1-800-465-6325, Monday–Friday
8 a.m.–5 p.m. (Eastern time)
Kodak, Advantix, Ektacolor, Ektacolor SM, Flexicolor, 
Flexicolor SM, Gold, Max, Prime, and Royal are trademarks.