Operator’s Manual
Operation
OPERATION
NOTE: Read Operator’s Manual carefully before operating this 
unit. Be certain to block the wheels to prevent the unit 
from  moving  while  operating.  Always  make  sure  the 
unit is level and properly grounded. Check engine oil 
before starting. 
1. Turn the idle control switch to the OFF position. (See Fig. 
3)
2. Move choke lever to full choke. If re-starting a warm engine, 
the choke should be left in the off position. (See Fig. 4)
3. Turn the key to the START position, hold until engine starts. 
4. When the engine starts, release key, allowing it to return to 
the ON position.
NOTE: Do not crank the engine continuously for more than  
  30  seconds  at  a  time.  If  the  engine  does  not  start,  allow  
  for a 3 minute cool down period between starting    
  attempts. Failure to follow these guidelines can damage  
  the starter motor.
    If the starter does not turn the engine over, shut off  
  the starter immediately. Do not make further attempts to  
  start  the  engine  until  the  condition  is  corrected.  Do  not  
  jump start using another battery.
5. Slowly move choke lever to no choke.
6. Allow unit to run two (2) minutes to warm-up.
7. Test the GFCI receptacle(s) on the unit. Push the test button. 
The reset button should pop out and there should be no 
power at the receptacle. Apply a test load or lamp to each 
receptacle to verify. IF THE RESET BUTTON DOES NOT 
POP OUT, DO NOT USE THE RECEPTACLES(S). SEE 
DEALER FOR SERVICE IMMEDIATELY.
8. If GFCI receptacle(s) test correctly, firmly push the reset  
button to restore power. A distinctive click should be heard or  
felt  when  this  is  complete.  IF  THE  RECEPTACLE(S)   
DO  NOT  RESET  PROPERLY,  DO  NOT  USE  THE   
RECEPTACLE(S).  SEE  DEALER  FOR  SERVICE   
IMMEDIATELY.
9. Turn idle control switch to ON position. Loads can now be  
applied to unit.
NOTE: This engine is equipped with a “Low Oil” shutdown  
 system for engine protection. The engine stops when  
 the  oil  level  gets  too  low.  The  engine  will  not  restart 
without  adding  oil.  Refer  to  Preparing  the  Generator; 
Engine Fuel Capacity for instructions on adding oil.
(Fig. 3)
(Fig. 4)