Ricoh FV-L200B1 用户手册

下载
页码 32
 
 
 
 
 
15/32 
FV-L200B1 
User’s Guide Rev. 1.01 
 
 
3.2 
Pulse Width Trigger Mode 
 
In  this  “pulse  width  trigger  mode”  with  positive  polarity,  the  camera  exposure  starts  at  the  rising  edge  of  the 
trigger  signal  and  stops  at  the  falling  edge  of  the  trigger  signal.  Therefore,  in  the  case  that  the  exposure  positive 
polarity is selected, the actual exposure occurs when the trigger signal is at high state. 
 
 
3.2.1 
Pulse Width Trigger Mode(V-Reset) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Note 1: The camera does NOT switch to normal mode when the long exposure mode is selected. 
This timing chart shows when the long exposure mode selected. 
Note 2: The internal VD signal is reset immediately after the exposure is finished as depicted, and the video output 
original is sent out according to that reset VD timing.   
Note 3: The exposure time is controlled by the pulse width of the trigger signal as depicted. 
 
 
Exposure
time
Max. 1H
Sweep charges
Automatically switch to the normal
 mode if the pulse width of the
trigger signal is more than
500 mseconds.
*Note. 1
Camera mode
Internal VD
CCD exposure
Trigger signal
(Positive)
Video out
*Note. 2
*Note. 3
FVAL
Normal mode
Trigger mode
Normal mode