3.10.8.  Trigger Mode 5   
This mode is “multiple shutter pulse width mode”.    The camera starts integration of the incoming light from the first 
external trigger input falling edge and exposes incoming light until the trigger is inactive. It repeats this sequence for 
the N-th (parameter) external trigger input falling edge and then the integration finishes. A Parameter is required and 
shall be one or more.    (N >= 1)   
 
 
3.10.9.  Trigger Mode 12 
Trigger mode 12 is only supported on Fire-i 701/702/810 cameras. The user can capture the multi frame rates with 
one trigger signal. The users can control the Gain and Shutter by the Parameter Table which has a range from 1 to 255.   