6.11 Digital Monitor Power 
Management 
 
 
DMPM is monitor power management applied over the digital DVI interface. TANDBERG 
supports DMPM in software F2 and above. Six monitor power states are defined. 
 
Monitor On Power state 
Transmitter (TANDBERG codec) and receiver (Monitor) are powered and active. This power state 
is equivalent with the DPMS normal mode. 
 
Intermediate Power state 
When the codec goes from active to standby, it turns off the DVI transmitter and the monitor can 
go from Monitor On  
 
Power state to Intermediate Power state 
 
Active-off Power state 
The monitor can go from Intermediate Power state to Active-off Power state when the monitor 
timer expires. 
 
Non-Link Recoverable Off Power State 
The monitor can enter Non-Link Recoverable Off Power State when the codec is switched off or if 
the DVI cable is disconnected. This power state is equivalent to the DPMS “Off (with no DPMS 
recovery)” state. 
 
Monitor Power Switch Off Power state 
This state can be entered when the power switch on the monitor is toggled to its off position. This 
state has two sub-states dependent on if the codec is switched on or off.