Pentax R-325(N) 用户手册

下载
页码 52
PSF Software Ver.365 
 
20 
Input the Foresight point number
 
Input the Foresight point Coordinates.
 
 
 
 
For store:    : Press the [STORE]
Not for store: Press the [ENT]
 
 
           
FORESIGHT COORDINATES INPUT
 
 
5
 
 
Press the [ENT] key to view the ANGLE 
COMPARE screen
.  
 
 
 
 
 
 
 
             
           
ANGLE COMPARE 
 
 
 
“BACKSIGHT SELECTION” screen explanation:   
 
  Go to Input or Call of BACKSIGHT NUMBER LIST in case of 1. COORDINATES INPUT selection of the 
BACKSIGHT SELECTION screen. 
 
  Go to the Operating procedures 2. FORESIGHT NUMBER LIST of 3. STAKEOUT in case of   
            2. FORESIGHT COORD. (AZIMUTH) INPUT selection of the BACKSIGHT SELECTION screen. 
 
                                                                                 
                                                                              BACKSIGHT SELECTION
   
 
 
 
 
 
 
 
1) 
 
Aim at the Backsight point and input the 
AZIMUTH angle in case of 2. 
FORESIGHT COORD. (AZIMUTH) INPUT 
selection
.
 
 
Press the [H. INPUT] at F2 key. 
 
 
 
              H. ANG INPUT 
2) 
 
For example, input the 225°  00'  00"
 . 
 
 
 
 
 
             
          H. ANG INPUT 
DESIGN     90°  00'  00" 
H.angle       0°  00'  00" 
DEVIATE    - 90°  00'  00"
 
 
 
       
H.INPUT 0 SET
 
ANG/DIST
 
 
 
 
 
000°  00'  00"
000°  00'  00"
 
 
2.DESCRIPTION  : 
3.X COORD.     :  xxxxxx.xxx m 
4.Y COORD.     :   xxxxx.xxx m 
5.Z COORD.     :     xxx.xxx m 
6.INST. H                :              x.xxx m 
 
            STORE                    SELECT 
1. COORDINATES INPUT                                 
2.FORESIGHT COORD.(AZIMUTH) INPUT