18) Press 
Enter
 to confirm. 
 
Quick Recall Function 
This function allows you to recall 10 groups numbers which were stored previously. 
Steps: 
1) Press
Shift
 +
Menu
 
2) Press▼to
 CONFIG, press
Enter
 into submenu, press▼ to
 SHORTCURT RECALL 
3) Press
Enter
, select
  >
ON and press
Enter
 to confirm. 
4) Press
ESC
  two times and quit the menu. 
5) Press
1
  and you can get the first group number. Press
2
, you can get the second group number. Press
0
you can get the tenth group number. And if there is not stored number, VFD will show
 NO EEPROM DATA
 
 
Automatic Testing Function of Electronic Load 
The CD load’s firmware provides an automatic testing function that is convenient for testing various 
parameters of power supplies with different load conditions. Now we take a kind of charger as an 
example to explain the usage of the automatic testing of the electronic load. 
The test proceeding of R35 charger 
Work produce 
process 
method 
 
Mode Voltage(V) 
Current(mA) 
Power(W) 
Ripple 
counter(mVpp) 
The first step 
CC 
5.8~6.15 
210 
≤4(input175VAC) 
The second step 
None 
5.9~6.4 
≤1.2(input175VAC) 
The third step 
CC 
205~245 
 
The fourth step 
CV 
205~245 
 
The fifth step 
CV 
205~245 
 
 
The sixth step 
Short 
circuit 
≤245 
 
 
 
 
≤50mVpp 
 
Edit the Testing File 
1) Press
Shift
 +
Menu
 
into menu, VFD displays  >
CONFIG 
2) Press▼ to >
LIST SET
3) Press
Enter
  into submenu, press▼ to>
EDIT LIST FILE