Installation
Internal PSII
28
45537L-005
ZebraNet PrintServer II User Guide
04/21/2009
To install an internal PSII into a XiII, XiIII, R140, 105SL, and PAX Series printer, 
complete these steps:
 
1.
2.
3.
From the back of the printer, remove the two screws and the blank cover plate positioned 
next to the main RS-232 and parallel interface connectors.
4.
Which printer model do you have?
Caution • 
A qualified service technician must perform this installation.
Tools • 
You need these tools to complete this procedure:
‰ Phillips Screwdriver Set
‰ 3/32 in. Allen Wrench
Caution • 
Observe proper electrostatic safety precautions when handling 
static-sensitive components such as circuit boards and printheads.
Connect yourself to an antistatic device.
Caution • 
Turn off (O) the printer and disconnect it from the power source before 
performing the following procedure.
Turn off (O) the printer and disconnect the AC power cord and all data cables.
If you have 
a(n)…
Then…
XiII, XiIII series, 
R140, or a 105SL
a.
Se
.
b.
To remove the side panel, remove the screws and remove the 
left side panel. 
PAX
a.
Se
.
b.
To remove the side panel, access the electronics by removing 
the mounting screws from the printer’s PCB access panel and 
sliding the panel out.