Panasonic AJ-P2C004HG 用户手册

下载
页码 206
112
Preparation: Mounting the lens and Performing the Flange Back and White Shading Adjustments
8
Repeat steps 5 to 7 until the lens is in focus at both the 
telephoto and wide-angle positions.
9
Firmly tighten the F.f ring clamping screw.
Method to correct the waveform to be more flat by 
combining the sawtooth-shaped waveform and the 
parabola waveform when watching the respective 
waveforms of R, G and B of the video signals.
Note
Coloring may occur in the vertical direction near where the 
lens aperture is open even when the white shading has been 
adjusted. This is something that is inherent to lenses and 
optical systems and is therefore not indicative of a failure or 
malfunctioning.
1
Attach the lens to the camera.
At this stage, do not forget to connect the lens cable.
2
Set the electronic shutter to OFF and the gain to “L 
(0 dB).”
3
If the extender is attached to the lens, release the 
extender function.
4
Perform a menu operation to open the <VF DISPLAY> 
screen from the VF page, check that the settings 
selected for the ZEBRA1 DETECT item, ZEBRA2 
DETECT item and ZEBRA2 item match the settings 
shown in the figure below. If they differ, make the 
appropriate changes, and then close the menu screen.
5
Set the ZEBRA switch on the viewfinder to [ON].
6
Shoot a white sheet of paper with no unevenness of 
color.
Note
Since fluorescent lights, mercury lamps and other such 
kinds of lighting tend to flicker, use a light source which 
is free from flicker such as sunlight or a halogen lamp.
7
Set the lens aperture control to manual, and adjust it so 
that the zebra pattern covers the whole screen.
Check that the lens aperture is between F4 and F10.
Notes
The zebra pattern will not cover the whole screen if 
there is any unevenness in the lighting. In this case, 
make adjustments to the position of the lighting, etc.
Make adjustments to the position of the lighting, etc. 
also when the lens aperture is not between F4 and 
F10.
Be absolutely sure to leave the electronic shutter at 
OFF.
9
Repeat step 7.
10
Using the menu operation, open the <WHITE 
SHADING> screen from the MAINTENANCE page and 
a range of items from R H SAW item to B V PARA item, 
so that the waveform is more flat.
11
When an extender is fitted to the lens, switch on the 
extender function, and repeat steps 7-9. The unit stores, 
as one lens file data item, two different correction 
values, one for when the extender is fitted and the other 
for when it is not fitted. When a ratio converter is 
inserted, the correction value for the latter correction 
value is used.
Adjusting the Lens White Shading
 














8
1
Set the WHITE BAL selector switch to [A] or [B], and 
use the AUTO W/B BAL switch to adjust the white 
balance automatically (AWB).
2
Use the AUTO W/B BAL switch to adjust the black 
balance automatically (ABB).
3
Again, use the AUTO W/B BAL switch to adjust the 
white balance automatically (AWB).


 











H SAW
H PARA
Before 
correction
After correction
AJ-HPX2700G-VQT1V27_eng.book  112 ページ  2008年9月2日 火曜日 午後5時43分