Panasonic AJ-P2C002SG 用户手册
26
Parts and their Functions: Display Window Functions
Display Window Functions
P2 card/battery-remaining level and audio level
indications
indications
a. Media-remaining space indication bar
The bar indicates the remaining free space on each P2 card,
using a 7-segment display.
Each segment can represent either 3 or 5 minutes of remaining
free space, depending on the value set through the menu option
CARD REMAIN/. According to the set value, the segments
disappear one-by-one. The menu option CARD REMAIN/ can
be found in the <BATTERY/P2CARD> screen on the MAIN
OPERATION page.
using a 7-segment display.
Each segment can represent either 3 or 5 minutes of remaining
free space, depending on the value set through the menu option
CARD REMAIN/. According to the set value, the segments
disappear one-by-one. The menu option CARD REMAIN/ can
be found in the <BATTERY/P2CARD> screen on the MAIN
OPERATION page.
b. Battery-remaining level indication bar
For a battery with a digital indicator (percentage indication), if the
remaining level of the battery is higher than 70%, all 7 segments
up to the “F” position are lit.
When the remaining level falls below 70%, the segments go out
one-by-one for each drop of 10%. All 7 segments can be set to
light up when the battery-remaining balance is 100%. To do so
select “100%” for the menu option BATT REMAIN FULL in the
<BATTERY/P2CARD> screen of the MAIN OPERATION page.
remaining level of the battery is higher than 70%, all 7 segments
up to the “F” position are lit.
When the remaining level falls below 70%, the segments go out
one-by-one for each drop of 10%. All 7 segments can be set to
light up when the battery-remaining balance is 100%. To do so
select “100%” for the menu option BATT REMAIN FULL in the
<BATTERY/P2CARD> screen of the MAIN OPERATION page.
c. Audio channel level meter
When the MONITOR SELECT CH1/2 / CH3/4 switch is set to
[CH1/2], the meter indicates 1 and 2 as the audio channel
numbers, together with their audio levels. When the switch is set
to [CH3/4], the meter indicates 3 and 4 as the audio channel
numbers, together with their audio levels.
[CH1/2], the meter indicates 1 and 2 as the audio channel
numbers, together with their audio levels. When the switch is set
to [CH3/4], the meter indicates 3 and 4 as the audio channel
numbers, together with their audio levels.
Memory action status indication
d. Error Code Indication (for more information, see [Warning
e. Information indication
LOOP:
Stays illuminated in LOOP REC mode. For
information about the LOOP REC mode, see [Loop
Recording] (page 40).
information about the LOOP REC mode, see [Loop
Recording] (page 40).
OP-SLOT: Remains illuminated when a video encoder card is
operated in the optional slot.
LOOP
h
MEDIA
E
F
Y
minM
s
frm
13
24
0
D
VTCG TIME DATE P-iREC
SLAVE HOLD
GPS
BATT
E
F
OVER
OVER
10
OO
40
-dB
30
20
HD
OP-SLOT
CTL
NDF
a
c
b
LOOP
h
MEDIA
E
F
Y
minM
s
frm
13
24
0
D
VTCG TIME DATE P-iREC
SLAVE HOLD
GPS
BATT
E
F
OVER
OVER
10
OO
40
-dB
30
20
HD
OP-SLOT
CTL
NDF
d
e
f. Mode indication
HD:
Stays illuminated when the unit is in HD mode (1080i,
720P).
720P).
GPS:
Stays illuminated when radio waves are not received
during GPS operation.
during GPS operation.
GPS
:
Stays illuminated when radio waves are received
during GPS operation.
during GPS operation.
P-REC:
Stays illuminated when the PRE REC MODE is set to
“ON”, and blinks when recording is continued after
the recording tally lamp has gone out.
“ON”, and blinks when recording is continued after
the recording tally lamp has gone out.
iREC:
Remains illuminated during INTERVAL REC mode
recording, and blinks during a pause.
recording, and blinks during a pause.
i:
Blinks when INTERVAL REC mode is selected.
g. Time code indication
NDF:
Stays illuminated when the time code is in non-drop
frame mode.
frame mode.
DF:
Stays illuminated when the time code is in drop frame
mode.
mode.
SLAVE:
Stays illuminated when the time code is externally
locked.
locked.
HOLD:
Stays illuminated when the time code generator/
reader value is frozen.
reader value is frozen.
CTL:
Stays illuminated when the DISPLAY switch is
positioned at [CTL] to display the CTL count.
positioned at [CTL] to display the CTL count.
TCG:
Stays illuminated when the DISPLAY switch is
positioned at [TC] (or [UB]) to display the TC (or UB)
generator value.
positioned at [TC] (or [UB]) to display the TC (or UB)
generator value.
TC:
Stays illuminated when the DISPLAY switch is
positioned at [TC] (or [UB]) to display the TC (or UB)
reader value.
positioned at [TC] (or [UB]) to display the TC (or UB)
reader value.
VTCG:
Stays illuminated when the DISPLAY switch is
positioned at [UB] to display the VIUB generator
value.
positioned at [UB] to display the VIUB generator
value.
VTC:
Stays illuminated when the DISPLAY switch is
positioned at [UB] to display the VIUB reader value.
positioned at [UB] to display the VIUB reader value.
TIME:
Stays illuminated when the DISPLAY switch is
positioned at [UB] to display the real-time hour,
minute and second.
positioned at [UB] to display the real-time hour,
minute and second.
DATE:
Stays illuminated when the DISPLAY switch is
positioned at [UB] to display the real-time date.
positioned at [UB] to display the real-time date.
No Indication:
The VTCG, TIME, and DATE stay off when the
DISPLAY switch is positioned at [UB] to display real
time, time zone, hour and minute.
DISPLAY switch is positioned at [UB] to display real
time, time zone, hour and minute.
Time count indication:
The time code, user bits, CTL and real time are
shown.
shown.
Note
When the DISPLAY switch is positioned at [UB], each press of the
HOLD button changes the indication through VTCG (VTC)
HOLD button changes the indication through VTCG (VTC)
DATE
TIME
No Indication (Time Zone)
TCG (TC), in that order.
LOOP
h
MEDIA
E
F
Y
minM
s
frm
13
24
0
D
VTCG TIME DATE P-iREC
SLAVE HOLD
GPS
BATT
E
F
OVER
OVER
10
OO
40
-dB
30
20
HD
OP-SLOT
CTL
NDF
g
f
AJ-HPX2700G-VQT1V27_eng.book 26 ページ 2008年9月2日 火曜日 午後5時43分