Konica Minolta T-10A /T-10MA/ T-10WSA/T-10WLA 用户手册

下载
页码 11
2
3
Illuminance Meter
 
 
T-10A series
Compatible with new, next-generation light sources including PWM-controlled sources.
For simple but accurate illuminance measurements. Makes creating illuminance 
measurement systems such as multi-point measurement systems easy!
 T-10A
 T-10MA/T-10W
S
A/T-10W
L
A
<Mini receptor >
<Standard receptor>
T-10MA  
(Cord length: 1 m)
Conforms to JIS AA Class  
and DIN class B
Enables illuminance 
measurements of small areas.
Can be used for illuminance 
measurements in narrow spaces 
where the standard receptor won't fit. 
It can also be easily installed on 
various kinds of equipment or jigs 
for measuring light levels such as 
illumination. 
T-10W
S
(Cord length: 5 m)
T-10W
L
(Cord length: 10 m)
Conforms to JIS requirements 
for special illuminance meters
The mini receptor and cord are both 
waterproof, so they can be used for 
measurements in water. 
They can be used for illuminance 
control for fishery-related applications 
(such as fish farming, etc.) or for 
measuring outdoor illuminance on 
rainy days.
T-10A
Conforms to JIS AA Class  
and DIN class B
Can be used for general 
measurements of illuminance.
Custom order
Waterproof
Reliable, worry-free illuminance meters that 
conform to JIS AA Class and DIN Class B
Illuminance Meters T-10A and T-10MA conform to Class AA of JIS 
C 1609-1: 2006 "Illuminance meters Part 1: General measuring 
instruments" and DIN 5032 Part 7 Class-B " Photometry; 
classification of illuminance meters and luminance meters" 
requirements to provide high-accuracy, high-reliability, worry-free 
measurements.
Illuminance meters conforming to these standards are required for 
measurements of general illumination light sources, white LED lamps 
for illumination, etc. in a variety of industrial fields.
Compatible with PWM-controlled lighting. Enables 
measurements of next-generation light sources. 
Conventional illuminance meters often cannot accurately 
measure PWM-controlled light sources, but the T-10A series 
of illuminance meters can be used to accurately measure 
even such light sources.
Removable receptor
The receptor and main body 
can be detached from each 
other and then connected 
using a LAN cable, making it 
easy to install as part of an 
inspection system.
 
z
9-point example: Projectors, etc.
 
 
z
5-point example: Architectural lighting, etc.
 
z
25-point example: Street lighting, etc.
 
z
Government testing organizations
 
z
Research/inspection at illumination 
equipment makers
 
z
Maintenance at factories, offices, hospitals, 
etc.
 
z
Illuminance control of security lighting, 
street lighting, etc.
 
z
Checking light sources for construction
 
z
Lighting control at LED-lit factory farms
 
z
As sensor for equipment measuring total 
flux or light-
distribution 
characteristics, 
etc.
M a i n   F e a t u r e s
Multi-point illuminance measuring system
Main applications
Receptor 
diffuser 
window: 
Ø 25 mm
Receptor 
diffuser 
window: 
Ø 14 mm
Cross-section A
illuminance (lx)
Horizontal distance (m)
H
ei
gh
(m)
0
0
1
1
2
2
3
3
4
-1
-2
-3
300
100
50
10
30
5
Easy, inexpensive multi-point measurement  
(2 to 30 points).
Illuminance distribution of a projector etc. can be easily 
measured with a single instrument and several receptors.
illuminance Measurement Trio
Illuminance Meter T-10A series
Illuminance Meter T-10A series