Fujifilm LAS-3OOO 产品宣传页

下载
页码 2
Specifications and Applications
Fuji Photo Film Co., Ltd. 26-30, Nishiazabu 2-Chome, Minato-ku, Tokyo 106-8620, Japan, Tel: +81-3-3406-2201, Fax: +81-3-3406-2158  •  http://lifescience.fujifilm.com  •  E-mail: sginfo@tokyo.fujifilm.co.jp
Fujifilm Medical Systems U.S.A., Inc. 419 West Avenue, Stamford, CT 06902, U.S.A., Tel: +1-203-324-2000 ext. 6112 (1-800-431-1850 ext. 6112 in the U.S.), Fax: +1-203-351-4713  •  http://www.fujimed.com  •  E-mail: SSG@fujimed.com
Fuji Photo Film (Europe) GmbH, Heesenstr. 31, 40549 Düsseldorf, Germany, Tel: +49-211-5089-174, Fax: +49-211-5089-139  •  http://www.fujifilm.de  •  E-mail: mkaling@fujifilmeurope.de
Specifications and system configuration subject to change for improvement without notice.   All other product names mentioned herein are the trademarks of their respective owners.
Re
f. 
No
. B
B-
20
4E
 (0
4,
09
)
LAS-3OOO
S u p e r   C C D  
R e m o t e   C o n t r o l l e d
S c i e n c e   I m a g i n g   S y s t e m
Image Capturing Unit (Camera Head and Controller)
CCD chip 
Fujifilm Super CCD Area Type chip 
    Number of pixels  
3.2M pixels 
    Pixel size                        10.75 x 10.75µm
Cooling 
Two-stage thermoelectric module with air circulation
Cooling temperature 
-30°C (when room is below 28°C)
Focusing 
Power focusing; remote and preset control 
Exposure time 
1/100 second to 30 hrs (2 hrs to 30 hrs to be set manually) 
Dynamic range 
Four orders of magnitude
Gradation 
16 bits (65,536)
Image size 
12.6MB Max.; 49.2KB Min.
Maximum sample size 
25 x 25cm (wide angle lens); 14 x 21cm (Fujinon VRF43LMD lens)
Binning 
1 x 2, 2 x 4, 4 x 8, and 8 x 16 pixels
Interface 
USB1.1
Software
Image capture 
Fujifilm Image Reader (Mac
 and Windows
®
)
Image analysis 
Fujifilm Image Gauge (Mac
); Fujifilm MultiGauge (Windows
®
)
Dimensions and Weights
Camera head 
180 (W) x 170 (H) x 250mm (D) 
3.4kg
Dark Box IV 
510 (W) x 730 (H) x 480mm (D) 
49.0kg
Analyzing Unit 
Operating system 
Windows
®
 XP or Mac
 OS 9 & X
Applicable Reagents and/or Samples
Chemiluminescence 
CDP-Star
®
, ECL
, ECL Plus
, SuperSignal, ImmunoStar, CSPD
®
Fluorescence 
EtBr (W/UV light), SYBR
®
 Green I & II, SYPRO
®
 Orange,  
   
GFP, DY-458XL (blue LED)
   
Pro-Q
 Diamond, Cy
3, RFP, DY-520XL (green LED), Alexa Fluor 633,  
   
Cy
5, DY-647 (red LED)
Chemifluorescence 
*AttoPhos
Digitization 
CBB-stained gel, Silver stained gel (Transilluminator) 
   
NBT/BCIP-stained membrane. MW marker (Epi-illuminator)
Intelligent Dark Box IV 
EPI-illuminator for fluorescence 
blue LED (470nm), green LED (520nm), red LED (630nm)
EPI-illuminator for digitization 
White-light source
Transilluminator - for digitization of 
 
  stained gels and autoradiographic films  
White LED   
UV transilluminator** 
 
UV-light source (312nm)
Filter turret                                      
Five positions
Printers
Pictrography 3500
Lens 
 
 
 
 
 
 
Lens 
High-sensitivity lens (FUJINON VRF43LMD) 
Wide-view lens
F-number 
0.85 
F-number 
2.0
Focal length 
43mm 
Focal length 
24mm
Focus 
Remote power focusing 
Focus 
Manual
Mount 
Bayonet 
Mount 
Adapter to Nikon F mount
Analysis
Set a tray
Remote controlled
focusing
Exposure
Sample is placed on a tray
Chemiluminescence
Fluorescence
Chemifluorescence
Digitization
Chemiluminescence Mode
Fluorescence
Chemifluorescence Mode
Digitize Mode
Sample
Filter
blue LED
green LED
red LED
UV trans-
illuminator
White light
epi-illuminator
White trans-
illuminator
The image analysis process captures images in three modes: 
chemiluminescence, fluorescence/chemifluorescence and digitization.
The binning mode of the LAS-3000 allows researchers to select from four 
binning settings to enhance both imaging sensitivity and image resolution.
*No license is granted for use of AttoPhos™ to detect nucleic acid on a nylon membrane.
**No license is granted for pre-labeling gel electrophoresis method with the UV transilluminator.