Toshiba MK6017MAP 用户手册

下载
页码 126
360014937 
Copyright ©2000 Toshiba corporation. All rights reserved. 
626 - 
11.6 Other timings 
 
See HOST INTERFACE section for timings which are not shown here. 
 
Function and Intervals 
Timeout 
 
• 
POWER ON TIMINGS 
 
 
 
From power on to BSY=1 
400 ns 
maximum 
 
From Power on to BSY=0, DRDY=1 
31 s 
maximum 
• 
SOFT RESET TIMINGS 
 
 
 
From soft reset assertion (SRST=1) to BSY=1 
400 ns 
maximum 
 
From soft reset negation (SRST=0) to drive ready (BSY=0, DRDY=1) 
10 sec 
maximum 
• 
HARD RESET TIMINGS 
 
 
 
From hard reset assertion to BSY=1 
400 ns 
maximum 
 
From hard reset negation to drive ready (BSY=0, DRDY=1) 
31 sec 
maximum 
• 
DATA IN COMMANDS 
 
 
 
From writing to command register to BSY=1 
400 ns 
maximum 
 
From BSY=1 to BSY=0, DRQ=1, INTRQ set (When the drive is in idle mode) 
20 sec 
maximum 
 
From BSY=1 to BSY=0, DRQ=1, INTRQ set (When the drive is in standby mode) 
35 sec 
maximum 
 
Drive Busy during data transfer 
    5 
µ
minimum 
• 
DATA OUT COMMANDS 
 
 
 
From writing to command register to BSY=1 
400 ns 
maximum 
 
From BSY=1 to BSY=0, DRQ=1 
400 ns 
maximum 
 
Drive Busy during data transfer 
    5 
µ
minimum 
 
From BSY=1 to INTRQ set (When the drive is in idle mode) 
10 sec 
maximum 
 
From BSY=1 to INTRQ set (When the drive is in standby mode) 
25 sec 
maximum 
• 
NON-DATA COMMANDS 
 
 
 
From writing to command register to BSY=1 
400 ns 
maximum 
 
From BSY=1 to INTRQ set (When the drive is in standby mode) 
17 sec 
maximum 
• 
DMA DATA TRANSFER COMMANDS 
 
 
 
From writing to command register to BSY=1 
400 ns 
maximum 
 
Table 11.6-1 Other timings.