Lucent Technologies 585-310-575 用户手册

下载
页码 80
REGISTRY Resource Type
Issue 1   July 1997
61
2. Verify/administer the screen information, as required. 
3. Repeat for the delivery trusted server. 
4. Enter 
ch imapi
 and verify/administer as required. 
5. When complete, enter the correct information in the Set Up Enhanced-List 
System Data window.
REGISTRY Resource Type
Alarm Code: 1
Event ID: ELA-registry01 
Alarm Level:
 Warning
Description:
  E-list registry lost, re-enter or restore. The ELA software has 
detected that registry database has disappeared.
Repair Action: 
1. Re-administer the registry:
a. Go to the Administer Enhanced-Lists window.
b. Use (F4) NEW E-LIST to re-enter the name of each Enhanced List, 
one at a time. (The individual members do not need to be 
re-entered.)
See 
Lucent I
NTUITY
™ Messaging Solutions Release 4 
Administration, 
585-310-564 for more detailed procedures.
2. If the alarm persists, restore system data from the nightly backup. See 
Chapter 3, “Common System Procedures,” in your maintenance book for 
instructions about restoring data. If you would prefer to have assistance 
with this restore, contact your remote maintenance center. 
Alarm Code: 2
Event ID: ELA-registry02 
Alarm Level:
 Minor
Description:
  Unable to write updated E-list registry.
Repair Action: 
This alarm requires intervention from the remote maintenance center.