Honeywell K14114 3/06 Rev.B 用户手册

下载
页码 72
LYNXR-I Installation and Setup Guide
 
 
- 39 - 
83 Enhanced Sequential Mode 
 
 
 
 
IA   
zz
 
 
IA    LC
 
 
Enroll mode
 
0 = advance to next zone to be enrolled 
1 = enter now and proceed to SERIAL NUMBER 
prompt (1b).  
For 4 button keys (zones 26-29, 30-33, 34-37, & 
38-41) the serial number will be enrolled to all four 
buttons. 
If enrolling a key, the panel will emit a long beep 
when entering a 1 to indicate that the present key 
set up is invalid. 
Notes:(1)  A valid template or key has 4 existing zones, 
each with a zone type, unique loop number. 
 
(2)  If the display automatically advances to "1A" 
rather than "1b" the configuration of the key 
is not valid. At that point copy template, 
skip, or return are the only legal entries. 
2 = copy the previous serial number entry from 
the buffer. 
 
Notes:(1)  Before you can copy a serial number you 
must first enter a serial number. If no serial 
is stored in the buffer and a copy is 
attempted the panel will emit a long beep 
indicating an invalid operation.  
 
(2)  Not applicable for 4 button key zones 26-29, 
30-33, 34-37, & 38-41. 
 
3 = view existing serial number. 
 
Note:  Only if “L” is displayed. If the “L” is not 
displayed the panel will emit a long beep. 
 
4 = copy the 4 button key template that has been 
set in zone numbers 26-29 (all zone para-
meters except serial numbers). (Only valid on 
zones 30-33, 34-37, & 38-41 that do not have 
serial numbers enrolled.)  
Notes:(1)  Template acceptance is indicated by two 
beeps after copying.  
 
(2)  A single long beep emitted when copying a 
indicates the template is not valid.  
 
9 = delete existing serial. Go to the (1A) prompt. 
For 4-button key, zones 26-29, 30-33, 34-37, 
& 38-41 have serial numbers. Delete all four 
at one time. 
 
Note:  Only if “L” is displayed. If the “L” is not 
displayed the panel will emit a long beep.  
 
[✻] = advance to next zone to be enrolled  
[#] = return to previous prompt (A) 
 
Note: If “L” is displayed, the serial number for this transmitter 
has already been entered, however, it may still be 
confirmed, viewed or deleted. 
 
If the transmitter’s serial number has not been previously entered, you 
may enter the enroll serial number mode (1A) by entering “1”, or copy 
the last serial number that was entered by entering “2”. 
 
If the transmitter’s serial number has been previously entered, you 
may, view the present serial number by entering “3”. If view is selected 
each digit will be re-displayed, and the keypad will beep once for digits 
1-6, and three times for the last digit. Once the serial number has been 
entered by either selecting a “1” or a “2”, you will return to this prompt 
with the “L” on the display. The serial number/loop number 
combination that was entered can be confirmed by getting two 
transmissions (fault and restore) from the RF or UR device or one 
transmission from the BR device. If a transmission is received that 
matches the serial number and loop number entered, the system will 
announce the Voice Descriptor for the loop followed by three beeps, and 
a “C” will be displayed indicating that the received serial number and 
loop number  transmission  has been confirmed to match. No further 
transmissions will be received. When confirming a 4 button key, only 
the serial number is confirmed, since it assumed that all loops are 
used. Pressing any key will allow a confirmation. 
 
*Long beep indicates illegal entries, or duplicate serial 
number/loop entry* 
 
When the last zone has been entered, the display will remain on that 
zone. To exit this mode and return to data field program mode, press 00 
at the ZONE NUMBER prompt. 
 
When all zones have been programmed, test each zone using the 
system’s Test mode. Do not use the Transmitter ID Sniffer mode for 
this, since it will only check for transmission of one zone on a particular 
transmitter, and not the zones assigned to each additional loop. 
 
For Zones 26-29, 30-33, 34-37, and 38-41 any loop can be used for RF 
enrollment. If enrolling via RF, it will be confirmed without additional 
transmissions.