Honeywell MK VIII 用户手册

下载
页码 326
Honeywell
MK VI  MK VIII EGPWS Installation Design Guide
Proprietary notice on title page applies
CAGE CODE: 97896
SCALE: NONE
SIZE: A
DWG NO: 060-4314-150
REV:
SHEET 
290
22
Timed Audio Inhibit (momentary)
23
Reserved for EGPWS Test command Bit
24
Steep Approach activated (alternate action)
25-28
Terrain Display Range (as specified in the table below)
29
Not Used
BITS 25 to 28 = Terrain Display Range (0.5 to 2000 NM) format as follows:
DISPLAY RANGE BIT ASSIGNMENTS
Bits 28-25
DEFINITION
Bits 28-25
DEFINITION
0000
0.5 NM
1000
150 NM
0001
1.0 NM
1001
200 NM
0010
2.5 NM
1010
300 NM
0011
5.0 NM
1011
500 NM
0100
10 NM
1100
1000 NM
0101
25 NM
1101
2000 NM
0110
50 NM
1110
600 NM
0111
100 NM
1111
1200  NM
6.2.49 Body Pitch Rate (326)
Body Pitch Rate
  Source:  AHRS / IOC
LABEL (Octal)  326
Units:  Deg/Sec
Max. Range:  +/-128 Degrees/Sec
Approx. LSB:  0.0156 Deg/Sec
Data Bits:  16 to 28 = 13
+ =  Nose Up
Sign Bit:  29
Pad Bits:  11 to 15
Transmit Interval (mSec):  10 to 20
Data Type:  2’s Complement Binary
SDI Bits:  9, 10
6.2.50 Body Roll Rate (327)
Body Roll Rate
  Source:  AHRS / IOC
LABEL (Octal)  327
Units:  Deg/Sec
Max. Range:  +/-128 Degrees/Sec
Approx. LSB:  0.0156 Deg/Sec
Data Bits:  16 to 28 = 13
+ =  Right Wing Down
Sign Bit:  29
Pad Bits:  11 to 15
Transmit Interval (mSec):  10 to 20
Data Type:  2’s Complement Binary
SDI Bits:  9, 10
6.2.51 Minimum Descent Altitude (170) – IOC Scaling
Minimum Descent Altitude
  Source:  IOC
LABEL (Octal)  170
Units: Feet
Max. Range:  
±
 65,536 Feet 
1
Approx. LSB: 1 Foot
Data Bits:  13 to 28 = 16
+ =  Above Sea Level (ASL)
Sign Bit:  29
Pad Bits:  9 to 12
Transmit Interval (mSec):  200
Data Type:  2’s Complement Binary
SDI Bits:  N/A 
2
Note 1: Some IOC configurations may only provide positive ranges (0 to 65536 feet), however the EGPWS supports both
positive and negative ranges (
±
65,536 feet) for all configurations.
Note 2: This label may be provided in a configuration with a single DH input or in conjunction with a selected MDA
input. For those configurations which provide DH and MDA on separate labels format 3 applies (Format 1 is 0/0
SDI, Format 2 is Left SDI used and Format 3 is no SDI.)
6.2.52 Normal Angle of Attack (236)
Normal Angle of Attack
 Source: IOC
LABEL (Octal) 236
Units: N/A
Max. Range: 0 to 1
Approx. LSB: 0.000031
Data Bits: 14 to 28 = 15
+ = N/A
Sign Bit:  N/A
Pad Bits: 11 to 13, 29
Transmit Interval (mSec):  80
Data Type:  2’s Complement Binary
SDI Bits: 9, 10