Honeywell 5894PI 用户手册

下载
页码 4
Page 1 
 
K5942V2   7/04 
5894PI 
PASSIVE INFRARED MOTION DETECTOR/TRANSMITTER 
 
INSTALLATION INSTRUCTIONS 
 
GENERAL INFORMATION 
The 5894PI Passive Infrared Motion 
Detector/Transmitter is a 10-year battery-
operated wireless device intended for use as 
part of a 5800 series wireless alarm system.  
Designed for use in commercial and residential 
installations, the 5894PI is a wall-mounted unit 
with a standard lens that provides wide-angle 
protection up to a range of 35 ft (10.6m). For 
best coverage, mount the detector so that the 
likely direction of intruder motion is across  the 
pattern.  
When installed per the guidelines, the Tier-
Balanced Optics technology in the 5894PI 
provides false alarm protection against pets 
and other animals up to 80 lbs. 
This document provides installation instructions 
for the 5894PI, but the installer must be familiar 
with the installation instructions for the 5800 
Wireless Alarm System with which the 5894PI 
is intended to be used. 
 
FEATURES 
•  Tier-Balanced Optics provides pet immunity 
against animals up to 80 lbs. 
•  Wireless operation for fast installation. 
• Dual-element pyroelectric sensor provides 
positive protection while minimizing false 
alarms. 
•  Selectable PIR sensitivity. 
•  Provision to turn LED on while Walk Testing 
(LED is turned off after testing). 
•  Tamper-protected cover and wall; detector 
transmits message if cover or detector is 
removed. 
•  Wall or corner mounting options. 
•  Patented Black Bug Guard. 
• Temperature 
compensation. 
 
SYSTEM DESCRIPTION 
Optical System 
The 5894PI uses efficiently designed Fresnel 
lenses with Tier-Balanced Optics. 
Radio Transmitter 
The built-in transmitter serves only as the 
communication link to the alarm system's 
Receiver/Control, and can send alarm, tamper, 
supervisory, and battery status messages to 
the system's receiver/control. The transmitter is 
not used for detection purposes. Each detector 
has a unique ID code permanently assigned at 
the factory. You must enroll this ID into the 
control system at the time of installation. This 
allows each detector used in the system to be 
uniquely identified. You must program the 
control to enroll the 5894PI as an "RF" type unit 
(i.e., supervised RF).  
To conserve battery life during normal 
operation, no more than one transmission 
sequence will occur within a 3-minute period. 
There is no such time restriction in Test mode 
(refer to the Walk Test section). 
 
 
 
SPECIFICATIONS 
Pet Immune Lens:  
35 ft x 45 ft (10.6m x 13.7m). 
28 zones (8 over, 8 long range, 8 intermediate, 
4 short-range). 
Pulse Processing:   
Intermediate, Standard, or Harsh, Installer-
selectable.  Note: For pet immune applica-
tions, see Special Instructions for 
Installations with Pets on page 3. 
Detectable Walk Rate:   
0.5–10 ft/Sec (0.15–3m/Sec). 
Mounting Height:   
7.0 ft (2.1m) 
Walk Test Indicator: 
Red LED with enable/disable link. 
Batteries:  
Three 3-volt Lithium batteries. Use only 
ADEMCO No. 466, Duracell DL123A, 
Panasonic CR123A, Sanyo CR123A, or Varta 
CR123A. 
0perating Temperature:   
32°F – 122°F (0°C - 50°C). 
Operating Humidity:   
Up to 95% RH (max.), non-condensing. 
Dimensions:  
3.0"W 5.0"H x 1.7"D 
(76.3mm x 127.0mm x 42.6mm). 
Approvals/Listings:  
FCC, IC, cULus, C-Tick 
0
22.5'
22.5'
10'
20'
30'
35'
0
7'
0
10'
20'
30'
35'
SIDE VIEW
TOP VIEW
ALTERNATE 
COUNT POLARITY
EACH ZONE CONSISTS 
OF 2 FIELDS
 
Figure 1. Protection Pattern 
BATTERY ACTIVATION/INSTALLATION 
1.  Remove front cover by pressing the front 
cover latch and lifting the cover off.  See 
Figure 2. 
 
 
Figure 2. Remove the Front Cover 
2. To 
activate
 the installed batteries, remove 
the battery pull-tab. (See Figure 3.)  Make 
sure the batteries remain firmly seated in 
the battery holders. 
 
Figure 3. Remove Pull Tab to  
activate batteries 
3. To 
replace
 the batteries, remove the old 
batteries from the holder.  Then, observing 
correct polarity, 
install three new Lithium 
batteries into the battery holders, as shown 
in Figure 4. Make sure the batteries are 
firmly seated. 
4.  Replace the cover (snap fit). 
 
Battery Caution 
Risk of fire, explosion, and burns. Do not 
recharge, disassemble, heat above 100°C, or 
incinerate. Dispose of used batteries promptly. 
Keep away from children.