DMP Electronics SCS-1R 用户手册

下载
页码 31
Digital Monitoring Products 
SCS-1R Installation Guide
24
pRIntout explanatIons
 
Printout Explanations
General Description
Note: UL central station applications must use a serial printer listed for Fire Protective Signaling Systems.
The SCS-1R prints out two general types of messages: changes in the system information and messages received 
from DMP Command Processor panels.  The message line for system changes is bracketed by double asterisks 
with the time of occurrence printed at the far right.  Messages from panels always list the account number first 
followed by the message and the time of occurrence.  The printout below is a typical page from an Activity Log.
ATLAS SECURITY SERVICE, INCORPORATED
      Wednesday 
5/1/03 
* *  ACTIVITy LOG * * 
Page number:  
  2
  
* *   SECURITy CONTROL SySTEM NUMBER CHANGED TO: 1.        
* * 8:01 a.m.
  
* *   LINE:   3 CONFIGURED AS:    DD 
PHONE NUMBER:  (214) 555-1212  
* * 8:02 a.m.
  
* *   DIALER PANEL NUMBER:     108 ADDED TO LINE:   1        
* * 8:04 a.m.
  
1-        1  zone: 
8  FRONT DOOR 
-   BURG 
ALARM 
 
 
8:18 a.m.
  
1-        1  zone:  
2  BACK DOOR 
-  BURG 
TROUBLE 
 
 
8:23 a.m.
  
1-        1   zone:  
2  BACK DOOR  
-   BURG 
RESTORE 
 
 
8:24 a.m.
  
1-        1   *  * AMBUSH *  *                
   
 
 
 
8:27 a.m.
  
1-        1  Area:  
1  OFFICE 
-  DISARMED  
Usr: 007 
 
 
8:31 a.m.
 
 
 
2  PLANT 
 
 
 
3  SHIPPING
 
1-        1  zone:  010  FRONT DOOR 
-  ByP 
Usr: 015 
 
 
8:33 a.m.
 
1-        1  Usr: 009 added to panel 
   
Usr: 002 
 
 
8:33 a.m.
 
1-        1  Permanent schedule for Tuesday  Area: 1  
 
 
 
8:35 a.m.
 
 
Open:   8:00  a.m.        Close:   5:30 p.m. 
Usr: 005
 
1-        1  Door access    Dr: 001 
Usr: 021 
 
 
 
8:36 a.m.
 
1-        1  WARNING:  Low standby battery 
   
 
 
 
8:38 a.m.
 
1-        1  zone:  37   SMOKE DET.  
-   FIRE 
ALARM 
 
 
8:40 a.m.   
System Messages
System messages are provided on the Activity Log printer to provide a permanent record of changes made to the 
system information.  The operator making the change is determined by referring to the last sign on.
Command Processor Messages
Messages from Command Processor panels are sent to the SCS-1R advising of various changes in the panel status.  
The messages print and/or display on the LCD.
Alarm, Trouble, and Restore
These messages are all formatted the same.  Alarm and Trouble messages print to the Activity Log and display on 
the LCD for acknowledgment.  
Fire and Supervisory restorals display on the LCD for acknowledgment and printed to the Activity Log while other 
restore messages print to the Activity Log only.
Ambush
The Ambush message prints and displays on the LCD for acknowledgment.
Opening and Closing
Openings and Closings reports list the areas that are armed or disarmed and the user name making the change.  
These messages can be from 1 to 8 consecutive lines and print to the Activity Log only.
Bypass and Reset
This message prints in a one line format listing the zone number, zone name, and user name making the change.  
The message prints on the Activity Log only.
Schedule Changes
This prints in a 2-line format listing the type of schedule, day of the week, opening and closing time, and the user 
name making the change.  This message prints on the Activity Log only.