99
Operating Modes
Section 4-3
4-3
Operating Modes
4-3-1
Operating Modes
Coordinator and Motion Control Modules have three operating modes that
control the user program.
PROGRAM
Programs are not executed and preparations, such as initializing the System
Setup and other settings, transferring programs, checking programs, force-
setting, force-resetting, and checking wiring can be executed prior to program
execution. Motion Control Module built-in I/O refreshing and Coordinator Mod-
ule cyclic refreshing are, however, executed in this mode.
MONITOR
Programs are executed, but some operations, such as online editing and
changing present values in I/O memory, are enabled for trial operation and
other adjustments.
RUN
Programs are executed but some operations, such as online editing and
changing the present values in I/O memory using CX-Programmer, cannot be
performed. The CX-Programmer can monitor the program execution status
(program and I/O memory monitoring). The main system operation is per-
formed in RUN mode.
Note
(1) The operating mode of Motion Control Modules cannot be changed inde-
pendently in Sync Mode. Always change the operating mode of the Co-
ordinator Module in Sync Mode.
(2) To debug Motion Control Module programs, change the Coordinator Mod-
ule to ASync Mode under the System Setup and change the operating
mode for that Motion Control Module.
4-3-2
Status and Operations in Each Operating Mode
PROGRAM, RUN, and MONITOR are the three FQM1 operating modes. The
following tables list status and operations for each mode.
Note
The following table shows the relationship of operating modes to tasks.
Mode
Program 
execu-
tion 
(See 
note.)
I/O 
refresh
External 
outputs
I/O Memory
CX-Programmer operations
Cleared 
areas
Retained 
areas
I/O 
Memory 
monitor-
ing
Program 
monitor-
ing
Program transfers Program 
check
System 
Setup 
changes
Program 
changes
Force-
set/reset
Chang-
ing timer/
counter 
SV
Chang-
ing timer/
counter 
PV
Chang-
ing I/O 
Memory 
PV
FQM1 to 
com-
puter
Com-
puter to 
FQM1
PROGRAM Stopped
Exe-
cuted
OFF
Clear
Retained OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
RUN
Per-
formed
Exe-
cuted
Con-
trolled by 
program
Controlled by pro-
gram
OK
OK
OK
×
×
×
×
×
×
×
×
MONITOR
Per-
formed
Exe-
cuted
Con-
trolled by 
program
Controlled by pro-
gram
OK
OK
OK
×
×
×
OK
OK
OK
OK
OK
Mode
Cyclic task status
Interrupt task status
PROGRAM
Disabled
Stopped
RUN
Enabled
Executed if interrupt condition is 
met.
MONITOR