Omron FQM1-MMP21 用户手册

下载
页码 414
209
Functions for Servo Drivers Compatible with Absolute Encoders
Section 7-7
7-7-11 Timing Chart of the Functions for Servo Drivers Compatible with 
Absolute Encoders
7-7-12  Sample Programs (Connecting an OMRON W-series Servo Driver)
Program Description
1,2,3...
1.
With the Motion Control Module set to MONITOR mode, turning ON
CIO 0000.01 (absolute origin define) presets the absolute origin as the ab-
solute offset.
2.
With the Motion Control Module set to MONITOR mode, turning ON
CIO 0000.00 (absolute servo operation start) presets the absolute present
value in A600 and A601.
Counter value is not changed 
while reading rotation data.
Min: (50+60) ms
Typ: (50+90) ms
Max: (50+260) ms
1 to 3 ms
Preset after 30 to 62.5 ms
50 ms
RUN Signal Output Bit
Absolute No. of Rotations 
Read (A610.07)
High-speed Counter Start Bit
(A610.00)
Absolute PV Preset Bit
(A610.06)
SEN output
Phase A 
Phase B
Absolute Present value
ON during 1 cycle
Initial incremental pulses
30 to 62.5 ms
User program
processing
Signals from 
Servo Driver
The 
latest 
value
Absolute No. of Rotations 
Read Completed Flag
If the absolute No. of 
rotations read was 
successful, SEN output 
stays ON.
The high-speed counter 
starts 50 ms after start of 
the absolute No. of 
rotations read.
Perform absolute PV preset 
within 30 to 50 ms after the 
read is completed.
Rotation data: 
Motion 
Control 
Module's 
internal 
processing
Serial data (rotation data) 
approx.15 ms