24Hr. Gas Zones
Sections [001] to [016]: Zones 1 to 16, 3-digit # = 012
When a 24Hr. Gas zone opens, whether it is armed or disarmed, 
the console will immediately generate an alarm. The SIA FSK 
reporting format includes specific report codes to identify the 
alarm as a Gas alarm.
24Hr. Heat Zones
Sections [001] to [016]: Zones 1 to 16, 3-digit # = 013
When a 24Hr. Heat zone opens, whether it is armed or disarmed, 
the console will immediately generate an alarm. The SIA FSK 
reporting format includes specific report codes to identify the 
alarm as a Heat alarm.
24Hr. Water Zones
Sections [001] to [016]: Zones 1 to 16, 3-digit # = 014
When a 24Hr. Water zone opens, whether it is armed or 
disarmed, the console will immediately generate an alarm. The 
SIA FSK reporting format includes specific report codes to 
identify the alarm as a Water alarm.
24Hr. Freeze Zones
Sections [001] to [016]: Zones 1 to 16, 3-digit # = 015
When a 24Hr. Freeze zone opens, whether it is armed or 
disarmed, the console will immediately generate an alarm. The 
SIA FSK reporting format includes specific report codes to 
identify the alarm as a Freeze alarm.
Zone Options
Sections [001] to [016] represent zones 1 through 16 
respectively as demonstrated in Figure 16 on page 13. After 
entering the 3-digit Zone Definition (see Zone Definitions on 
page 13), select one or more of the following Zone Options by 
using the Feature Select Programming Method (see page 11):
Auto-zone Shutdown
Sections [001] to [016]: Zones 1 to 16; Option [1]
Option [1] OFF =Auto-zone Shutdown disabled
Option [1] ON =Auto-zone Shutdown enabled (default)
If, in a single armed period, the number of alarms generated by a 
zone with the Auto Zone Shutdown option enabled exceeds the 
number defined by the Auto Zone Shutdown Counter, the 
console will no longer generate an alarm for that zone. The Auto
Zone Shutdown Counter resets every time the system is armed.
Auto-zone Shutdown Counter
Section [067]: 001 to 015 alarms; 000 = Disabled; Default = 
5 alarms
Enter the desired limit into section [067] to program the 
Auto-zone Shutdown Counter.
Bypass Option
Section [001] to [016]: Zones 1 to 16; Option [2]
Option [2] OFF =Bypass option disabled
Option [2] ON =Selected zone is bypass enabled (default)
When a user uses the Bypass Programming feature, only zones 
with the Bypass option enabled can be programmed as 
bypassed.
Fire zones cannot be programmed with the Bypass option 
because the console will not bypass a Fire zone.
Alarm Types
Sections [001] to [016]: Zones 1 to 16; Options [4] and [5]
When an alarm condition occurs, the console can be 
programmed to react as shown in Table 2 on page 15.
Table 2: Alarm Type Options
The Alarm Type options cannot be programmed for Fire 
zones. Fire zones are automatically programmed with an 
audible pulsed alarm. This cannot be altered.
Intellizone
Sections [001] to [016]: Zones 1 to 16; option [6]
Option [6] OFF =Intellizone disabled (default)
Option [6] ON =Intellizone enabled
This feature reduces the possibility of false alarms. When a zone 
with the Intellizone option opens, the console does not 
immediately generate an alarm. First it triggers the Intellizone 
Delay TimerIf any of the following conditions occur during this 
period, the panel will generate an alarm:
During the Intellizone Delay, a second zone has caused an 
alarm.
During the Intellizone Delay, the zone in alarm has restored 
(closed) and re-occurred (opened).
The zone in alarm is still open after the Intellizone Delay has 
elapsed.
Options
Description
[4]
[5]
OFF
OFF
Audible steady alarm (default)
When the conditions for an alarm have been 
met, the control panel can transmit the 
appropriate Zone Alarm report code (see 
page 24) and provides a steady output for the 
on-board siren.
OFF
ON
Audible pulsed alarm
When the conditions for an alarm have been 
met, Magellan can transmit the appropriate Zone 
Alarm report code (see page 24) and provides a 
pulsed output (see Figure 17 on page 14) for the 
on-board siren.
ON
OFF
Silent alarm
When the conditions for an alarm are met, the 
control panel can transmit the appropriate Zone 
Alarm report code (see page 24) and will not 
activate the control panel’s bell output. The 
appropriate 
ARM
 or 
STATUS
 LED on the keypads 
will flash to indicate an alarm and the user will 
still have to disarm the system.
ON
ON
Report only
When the conditions for an alarm have been 
met, the control panel can transmit the 
appropriate Zone Alarm report code (see 
page 24). The system will not have to be 
disarmed.