Biamp Audia & Nexia 
When using the Base Station along with a Biamp  DSP, you must select the corresponding DSP 
product line from the “Serial  Control Processor” menu in the Revolabs HD Control Panel software. 
You must also set the RS-232 or Network settings of the Base Station to match the communication 
settings of the Biamp DSP as well as select the ‘Audio Channels’ of the microphones that the Base 
Station is to simulate.(i.e. 1-8, 9-16, etc.)  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Each Base station will control the mutes of a “level block”, within the DSP programming, using that 
block’s instance ID tag. The tags are as follows: 
 
Audio Channels 1-8  
MUTE1 
 
Audio Channels 9-16 
MUTE2 
 
Audio Channels 17-24 
MUTE3 
 
Audio Channels 25-32 
MUTE4 
 
Audio Channels 33-40 
MUTE5 (EU & CN Versions only)