Avaya 03-300430 用户手册
Communication Manager Maintenance-Object Repair Procedures
1910 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Link Retry Test (#215)
This test sends a message to the CDR software process to make a data call to the extension
where the CDR output device connects to. If the CDR link is already up, then this test will be
passed without making any data call.
where the CDR output device connects to. If the CDR link is already up, then this test will be
passed without making any data call.
Table 699: Test #215 Link Retry Test
Error
Code
Code
Test
Result
Result
Description / Recommendation
10
ABRT
Internal system error.
20
ABRT
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
30
ABRT
Internal system error.
1. See
instructions.
1010
ABRT
The CDR link has been busied out to out-of-service.
1. Enter release cdr-link primary | secondary to release the
CDR link from busyout state.
2. Retry test cdr-link primary | secondary long to execute
the test.
2012
ABRT
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
The CDR link CANNOT be established.
1. See
instructions.
PASS
The CDR link is up.