Communication Manager Maintenance-Object Repair Procedures
2344 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Notes:
a. Error Type 0: run the short test sequence first. If every test passes, run the long test 
sequence. Refer to each appropriate test’s description, and follow its recommended 
procedures.
b. Error Type 1: this error indicates the circuit pack totally stopped functioning or it was 
physically removed from the system.
Note:
Note:
The alarm is logged approximately 11 minutes after the circuit pack is removed/
SAKI Sanity test (#53) fails.
If the circuit pack is not present in the system, insert a circuit pack in the slot indicated by 
the error to resolve the error.
If the circuit pack is present in the system, it is faulty and must be replaced. See 
If the faulty circuit pack is in standby mode, a MINOR alarm is raised, but no other system 
action is taken. If the circuit pack is the active Tone-Clock, further effects of this error 
depend on the system’s reliability option.
3856 (
MAJ
ON
set tone-clock 
location override
3857
3858 (
)
NONE
MAJ
ON
busyout/release 
ipserver-interface
3872 (
0
None
set tone-clock 
location override
3999 (
Any
None
1. *For a TN2312 IPSI supported port network, use the command set ipserver-interface.
2. Minor alarms on this MO may be downgraded to Warning based on the value in set options
Table 839: Effects of Tone-Clock Failures Depending on Reliability 
Reliability Option
Effects
Standard
EPN goes down
Duplex
PN goes down.
 1 of 2
Table 838: Tone-Clock Circuit Pack Error Log Entries  (continued)
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
 2 of 2