Avaya 03-300430 用户手册

下载
页码 2574
Communication Manager Maintenance-Object Repair Procedures
398 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
1018
ABRT
The test has been disabled by administration. The default for the Test field 
on the station screen is y. Determine why this field was set to n on this 
station. It may be due to the brief ringing disturbance that this test may 
cause.
1. To enable the test for the particular analog station being tested, enter 
change station extension and set the Test field on the station 
to y.
2000
ABRT
Response to the test request was not received within the allowable time 
period.
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABRT
Could not allocate necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
The terminal equipment is not connected to the circuit pack.  Some 
terminal equipment, such as modems, may fail even when connected 
properly.
1. Remotely test the equipment.
2. If the test fails again, look for RING-GEN errors in the Error Log.
3. Check all of the wiring between the station equipment and the switch.  
Then, run the test again.
4. If the test still fails, the set may be defective.  Check the set, and 
replace it, if necessary.
5. Some terminal equipment could fail even when it is connected 
properly. If this is the case, disable the test using change station 
extension
 (enter n into the Test field). Note that this action also 
disables Tests 6, 7, 161, and 35 on this port.
PASS
The station is connected properly to the switch.  This test may also pass if 
no terminal equipment is connected and the terminal is located very far 
from the switch.  Investigate user-reported troubles on this port by using 
other port tests or by examining the station and its wiring.
Table 117: Test #48 Station Present Test  (continued)
Error 
Code
Test
Result
Description / Recommendation
 2 of 3