Error log entries and test to clear values
Notes:
a. Error type 0: Run the short test sequence first. If every test passes, run the long test
sequence. Refer to each appropriate test’s description, and follow its recommended
procedures.
procedures.
b. Error Type 1: these are inline errors and can only be resolved over time.
●
Aux Data 40960 indicates that too many simultaneous incoming ringing attempts were
made on this board. Only 4 ports on a board may ring simultaneously. A 5
made on this board. Only 4 ports on a board may ring simultaneously. A 5
th
incoming
call causes an inline error from the board.
Table 125: Analog line port error log entries
Error
Type
Type
Aux
Data
Data
Associated Test
Alarm
Level
Level
On/
Off
Board
Off
Board
Test to Clear Value
0 (
)
0
Any
Any
Any
test port location sh r 1
1 (
)
40960
40975
40977
none
Any
Audits and Updates test (#36)
18
0
busy station extension
WRN
ON
release station extension
130 (
None
WRN
ON
test port location sh
257 (
40973
None
513 (
Station Present test (#48)
WRN
OFF
test port location sh r 2
769
Battery Feed test (#35)
MIN
WRN
1
1. Minor alarms on this MO may be downgraded to Warning alarms based on the values used in set
options.
ON
test port location sh r 2
1025
Looparound test (#161)
MIN
WRN2
ON
test port location l r 2
1281
Conference test (#7)
MIN
WRN2
ON
test port location l r 2
1537
NPE Crosstalk test (#6)
MIN
WRN2
ON
test port location l r 2