Avaya 03-300430 用户手册

下载
页码 2574
Server Alarms
60 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
ENV (Environment)
S8700 | 8710
 / 
S8300
 / 
S8500B
The ENV MO monitors environmental variables within the server, including temperature, 
voltages, and fans. 
on page 60 describes the ENV 
MO’s alarms and their troubleshooting procedures.
Table 15: ENV Alarms in Media Server 
Event
ID
Alarm
Level
Alarm Text, Cause/Description, Recommendation
1
MAJ
“Temperature reached critical low” — Motherboard's temperature reached 
a critically low level.
1. See if the alarmed condition is still present, either from the:
- Web interface, by selecting the View Temperature/Voltage 
diagnostic
- Linux command line, by entering environment
2. If not, manually clear the alarm, either from the:
- Web interface, by selecting Alarms and Notification, the 
appropriate alarm, and Clear
- Linux command line, by entering almclear -n #id
2
MIN
“Temperature reached warning low” — Motherboard's temperature 
reached a warning low.
1. See if the alarmed condition is still present, either from the:
- Web interface, by selecting the View Temperature/Voltage 
diagnostic
- Linux command line, by entering environment
2. If not, manually clear the alarm, either from the:
- Web interface, by selecting Alarms and Notification, the 
appropriate alarm, and Clear
- Linux command line, by entering almclear -n #id
 1 of 8