Avaya 03-300430 用户手册
ATM-TRK (Circuit Emulation Service Circuit Pack)
Issue 1 June 2005
637
ATM Board Error Query Test (#1259)
This nondestructive ATM Error Query test retrieves the most severe, active, on- and off-board
problem from the ATM-TRK circuit pack’s firmware and increments error counts in the Error Log.
The test passes if there are no errors and fails otherwise. A passing test clears the software
counters; a failure increments the counter associated with the problem that caused the failure
and clears the others.
problem from the ATM-TRK circuit pack’s firmware and increments error counts in the Error Log.
The test passes if there are no errors and fails otherwise. A passing test clears the software
counters; a failure increments the counter associated with the problem that caused the failure
and clears the others.
Table 215: ATM Board Error Query Test (#1259)
Error
Code
Code
Test
Result
Result
Description / Recommendation
2000
ABRT
Test request timed out.
2031
ABRT
SCD failure. Unable to send down-link message.
1. Retry the command at 1-minute intervals up to 3 times.
2100
ABRT
Could not allocate needed system resources.
1. Retry the command at 1-minute intervals up to 5 times.
2500
ABRT
Internal system error
1. Retry the command up to 3 times at 1-minute intervals.
XXYY
FAIL
On-board error XX (
on page 638) and/or off-board error YY (
1. Examine the error logs and repair any errors found.
PASS
The ATM circuit pack has passed this test. No service effecting errors/
alarms have been detected on board.
0
NO
BOARD
ATM-TRK circuit pack not found
1. Check the error log, and correct Error 125 (wrong board) or Error 131
(no board), if found.
2. Make sure that the board is properly translated and inserted.
3. Check for hyperactivity (Error 1538). Run reset board location if
hyperactive.
4. Run the test again. If it fails, replace the board, and retest.