Avaya 03-300430 用户手册
Communication Manager Maintenance-Object Repair Procedures
882 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Notes:
a. See
on page 1134 for a description.
b. See
on page 1246 for a description.
c. See
on page 1942 for a description.
Single-Carrier Cabinet Power Query Test (#79)
This test queries an PN’s Maintenance circuit pack about the power’s status in a single-carrier
cabinet PN. This test can only detect power problems in the carriers of the PN where the Carrier
Port Power Supply physically resides.
cabinet PN. This test can only detect power problems in the carriers of the PN where the Carrier
Port Power Supply physically resides.
Table 302: Test #79 Single-Carrier Cabinet Power Query Test
Error
Code
Code
Test
Result
Result
Description / Recommendation
1000
ABRT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2000
ABRT
Response to the test request was not received within the allowable time
period.
period.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to ABORT with a 2000 error code, check for and
resolve every MAINT (Maintenance circuit pack) error. Repeat the test.
3. If the test still aborts with this error code, escalate the problem.
2029
2319
2320
2500
ABRT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
1 of 2