Bosch D1255B 用户手册

下载
页码 8
D1255/D1255B | Installation Instructions | 2.0  Digital Keypad 
 
 
Bosch Security Systems | 8/04 | 74-06819-000-F 
 
2.0   Digital Keypad 
The D1255/D1255B Keypad features a digital keypad 
for accessing the menus, entering user passcodes and 
executing system commands in the control panel. As 
you press keys, the D1255/D1255B emits a muted 
beep tone (refer to Section 2.3 Audible Tones) to indicate 
that the entry is accepted. The keypad lights when you 
press keys, and remains lit for 20 sec. 
When entering a passcode, press keys within 15 sec of 
each other. If 15 sec elapse between keystrokes, the 
entire entry clears, and you must start over. The 
keypad also "times out" on other functions if you wait 
15 sec or more between key presses. 
2.1 
Keypad Function Keys 
The D1255/D1255B has five function keys. These keys 
control your system. 
Table 1:  Function Keys 
 
Key Description 
COMMAND 
Use the [COMMAND] bar in combination 
with one or two numeric keys to perform a 
function. 
ENT/YES  
Use the [ENT/YES] key to complete the 
entry of your passcode at the keypad.  
The [ENT/YES] key also selects the menu 
item shown during a menu selection. 
PREV  
When viewing a list, pressing the [PREV] 
key returns you to the previously shown 
item. 
NEXT  
Press the [NEXT] key to pass over the 
present item in a menu or list. 
MENU/ESC 
Use the [ESC/MENU] key to returns to 
the idle display. 
 
2.2 Display 
The D1255/D1255B Keypad displays the latest status 
conditions of the security system using words, numbers, 
and symbols in its display. When a series of events 
occur that affects the system, the D1255/D1255B 
displays each event in order of its priority. 
For a complete listing and description of the 
D1255/D1255B 16-character displays and command 
functions available, consult the following 
documentation: 
For the D9412G, D7412G, D7212G, D9124, D9412, 
D9112, D7412, and D7212 Control Panels consult 
Security System User’s Guide (P/N: 71-06141-000) and the 
D9412G/D7412G Program Entry Guide (P/N: 47775). 
2.3 Audible 
Tones 
The D1255/D1255B Keypad has a built-in speaker that 
produces several distinct warning tones. The speaker 
volume is changed by adjusting the potentiometer 
(refer to Item 5 in Figure 2 on page 4). Turn the 
potentiometer clockwise to increase volume and 
counterclockwise to decrease volume. The speaker 
volume also changes as you adjust the brightness of the 
display. Refer to Command 49 “Dim Display” in the 
Security System User’s Guide (P/N: 71-06141-000) for 
more information. You cannot connect external 
annunciation devices to the D1255/D1255B. The tones 
in Table 2 are silenced by entering a programmed 
passcode with the appropriate authority. 
 
Table 2:  Audible Tones 
 
Tone Description 
Burglary 
Signal 
When an area is in alarm, the D1255/D1255B 
emits a steady, high-pitched “bell” tone.  
Entrance 
Warning 
The D1255/D1255B emits an intermittent beep 
tone during entry delay periods to remind the 
user to disarm the area. This is a programmable 
option. 
Exit 
Warning 
The D1255/D1255B emits an intermittent beep 
tone during exit delay and counts down the 
number of seconds left until arming takes place. 
This is a programmable option. 
Fire Signal 
When an area is in fire alarm, the 
D1255/D1255B emits a pulsed, high-pitched 
“bell” tone.  
Invalid Key 
Buzz 
Pressing an invalid key, or sequence of keys, 
causes the D1255/D1255B to emit a flat buzz 
tone. 
Keypad 
Encoding 
Tone 
The D1255/D1255B emits a muted beep tone 
as each key is pressed to indicate that the entry 
is accepted. To disable this feature refer to 
Section 3.3.1 Setting the DIP Switches on 
page 5. 
Trouble 
Buzzer 
When a trouble event occurs, such as a service 
alert, the D1255/D1255B emits a two tone 
warble until you enter COMMAND 4. 
Watch 
Tone  
When you activate the Watch feature, an 
intermittent beep tone (the same as the 
Entrance Warning Signal) alerts the user 
anytime a watch point is faulted. This option is 
programmable by point.