Bosch DS7445I 用户手册

下载
页码 100
DS7400Xi ( 4+) Reference Guide
Copyright © 2007 Bosch Security Systems, Inc.
P/N: F01U035325-01     Page 11
4.0
Hardware Layout Example
Armed
St atu s
Power
Fire
1
2
3
4
5
6
7
8
9
0
*
#
On
No
Ent ry
System
Re set
Bypass
On ly
Pe rim eter
Off
Perimete r
Su pe rvis ory
Be ll Silenc ed
Tro ubl e
1 2
3
4 5 6
7
8
®
DS7488 Octal
Relay Board
DS7400Xi
+
+
Power
Bus
DS7420i Dual Phone
Line/Bell Supervision
Module
DS7447/DS7447E and DS7445/DS7445i
Keypads
R
DS7450/52 Series Contacts, DS7460 Input Modules,
DS7465 Input/Output Modules, MX540, MX775,
MX794, MX835,  MX934, MX938, and MX950 motion
detectors and MX280 Series Smoke Detectors
DS7430
Keypads #11 - #15 must be connected to
the Options Bus. Keypads #1 - #10 must
be connected to the Keypad Bus.
Note:  Ensure at least 1/4" separation
between battery wires and all
other cabling.
Armed
St atu s
Po wer
Fire
1
2
3
4
5
6
7
8
9
0
*
#
On
No
Entry
Syste m
Reset
Byp ass
O nly
Per imete r
Off
Arme d
Stat us
Powe r
F ire
1
2
3
4
5
6
7
8
9
0
*
#
On
No
Entr y
Sys tem
Reset
Byp ass
O nly
Per imete r
Off
Armed
St atu s
Po wer
Fire
1
2
3
4
5
6
7
8
9
0
*
#
On
No
Entry
Syste m
Reset
Byp ass
O nly
Per imete r
Off
Armed
St atu s
Po wer
Fire
1
2
3
4
5
6
7
8
9
0
*
#
On
No
Entry
Syste m
Reset
Byp ass
O nly
Per imete r
Off
Armed
St atu s
Po wer
Fire
1
2
3
4
5
6
7
8
9
0
*
#
On
No
Entry
Syste m
Reset
Byp ass
O nly
Per imete r
Off
Armed
St atu s
Power
Fire
1
2
3
4
5
6
7
8
9
0
*
#
On
No
Ent ry
System
Re set
Bypass
On ly
Pe rim eter
Off
Perimete r
Su pe rvis ory
Be ll Silenc ed
Tro ubl e
1 2
3
4 5 6
7
8
®
Armed
St atu s
Power
Fire
1
2
3
4
5
6
7
8
9
0
*
#
On
No
Ent ry
System
Re set
Bypass
On ly
Pe rim eter
Off
Perimete r
Su pe rvis ory
Be ll Silenc ed
Tro ubl e
1 2
3
4 5 6
7
8
®
B
G
Y
+ – –
 Option
Bu s
Batte ry
Bell Outp ut
Au xiliary
Out put
+
+
+
+
+
G
R
B
1
2
3
4
5
6
7
8
9
10
Y
1 12 1 3 1 4 15 16 17 18 1 9 20 21 22 23 24 25 2 6 27 28
Battery
Battery
RF3222  120-Zone
Wireless Receivers
Wireless Sensors
R
T
R
T
T T
R R
T
R T
R
DS7432  8-Input
Remote Modules
47k
Ω
Dry contact inputs
+ – + –1
2 3
4 5
6 7
8
POWER BUS
+ – + –1
2 3
4 5
6 7
8
POWER BUS
+ – + –1
2 3
4 5
6 7
8
POWER BUS
+ – + –1
2 3
4 5
6 7
8
POWER BUS
1
2 3
4 5
2 G 1
-
+
BUS
NO
+
1
2 3
C NC
DS7416i
Communications
Module
EOL
• Up to 15 keypads may be used. Keypads #1 - #10 connect to the Keypad Bus and keypads #11 - #15 
connect to the Option Bus. One keypad must be designated as keypad #1 and connected to the Keypad 
Bus. See the DS7447/DS7447E, DS7445/DS7445i, and DS7448 Installation Instructions for further details.
• A DS7420i (Dual Phone Line/Bell Supervision Module) may be connected to the Control Panel, and 
placed within the enclosure. Connect to the Options Bus of the control panel. See the DS7420i Installation 
Instructions for further details.
• A DS7430 or a DS7436 (Multiplex Expansion Module) may be connected to the control panel via the 
expansion port. This will allow for the connection of additional zones via the Options Bus. See the DS7430
or DS7436 Installation Instructions for further details.
• Up to 2 DS7488s (Octal Relay Modules) may be connected to the Control Panel, and placed within the 
enclosure. Connect to the Options Bus of the Control Panel. This provides an additional 8 Form “C” 
relay outputs for the Control Panel. See the DS7488 Installation Instructions for further details.
• A DS7416i Advanced Radio Communications Module may be connected to the Control Panel via the Options
Bus. This allows for connection to a radio network.
• Up to 248 zones are available for the connection of Single, Multiple, Input/Output, and Multiplex devices.
Up to 112 wireless zones (137-248) are also available.
• Up to 2 RF3222 (120-Zone Wireless Receivers) may be connected to the DS7430 or DS7436. Connect to 
the Power and Bus terminals of the Multiplex Expansion Module. This allows for the monitoring of wireless 
detectors.
• Up to 30 DS7432s (8-Input Remote Modules) may be connected to the DS7430 or DS7436. Connect to the
Power and Bus Terminals of the Multiplex Expansion Module. This allows for a means of addressing  up to
240 input loops of conventional contacts to the Control Panel. See the DS7432 Installation Instructions for
further details.
1
2
3
4
5
6
7
8
9
0
*
#
On
No
Ent ry
Syst em
Re set
Byp as s
O nly
Per imete r
Off
TEST WEEKLY
1 2 3
4 5
6 7
8
9 1 0 11 12 13 14 15 16
Armed
Sta tus
Pow er
F ire
Pe ri met er
Su p erv isory
Bell Sile nce d
Trou ble
1
2
3
4
5
6
7
8
9
0
*
#
On
No
Ent ry
Syst em
Re set
Byp as s
O nly
Per imete r
Off
TEST WEEKLY
1 2 3
4 5
6 7
8
9 1 0 11 12 13 14 15 16
Armed
Sta tus
Pow er
F ire
Pe ri met er
Su p erv isory
Bell Sile nce d
Trou ble
1
2
3
4
5
6
7
8
9
0
*
#
On
No
Ent ry
Syst em
Re set
Byp as s
O nly
Per imete r
Off
TEST WEEKLY
1 2 3
4 5
6 7
8
9 1 0 11 12 13 14 15 16
Armed
Sta tus
Pow er
F ire
Pe ri met er
Su p erv isory
Bell Sile nce d
Trou ble