Vanguard Heating VP2000BTC 用户手册

下载
页码 32
26
103876
TECHNICAL
SERVICE
You may have further questions about installation, operation, or troubleshooting.
If so, contact DESA International’s Technical Service Department at 1-800-323-5190.
SPECIFICATIONS
SERVICE
HINTS
When gas pressure is too low
• pilot will not stay lit
• burner will have delayed ignition
• heater will not produce specified heat
• propane gas supply may be low
When gas quality is bad
• pilot will not stay lit
• burner will produce flames and soot
• heater will backfire when lit
You may feel your gas pressure is too low or gas quality is bad. If so, contact your
local propane gas supplier.
VP2000BTC
VP2800BTC
Btu (Variable)
10,000/20,000
15,000/30,000
Type Gas
Propane Only
Propane Only
Ignition
Piezo
Piezo
Pressure Regulator Setting
8" W.C.
8" W.C.
Inlet Gas Pressure (in. of water)
Maximum
14"
14"
Minimum
11"
11"
Dimensions, Inches (H x W x D)
Heater (Includes knobs & grill) 23.5 x 18.5 x 8.0
23.5 x 25.9 x 8.0
Carton
26 x 20.5 x 9.63
26 x 27.75 x 9.63
Weight (pounds)
Heater
22
30
Shipping
27
35