TROUBLESHOOTING
Note  :        All          troubleshooting
items    are    listed    in  order    of
operation.
    WARNING:  Only    a   qualified
service  person  should  service and
repair  heater.
   CAUTION:   Never  use  a  wire,
needle,  or  similar  object   to  clean
ODS/pilot.    This    can    damage
ODS/pilot  unit.
OBSERVED  PROBLEM
When  ignitor  button  is  pressed  and
control knob is pressed in and turned to
the PILOT position, there  is  no  spark
at  ODS/pilot.
ODS/pilot    lights   but flame   goes out
when   control   knob is released.
When  ignitor  button  is  pressed and
control knob is press in and turned to
the PILOT position, there  is  a spark
at  ODS/pilot  but  no ignition.
POSSIBLE  CAUSE
1.   Ignitor electrode is positioned
      wrong.
2.   Ignitor electrode is broken.
3.   Ignitor electrode is not connected
       to ignitor cable.
4.   Ignitor cable  pinched  or wet.
5.   Broken ignitor cable.
6.   Bad piezo ignitor.
1.  Gas   s upply    t urned    of f    or
     equipment shutoff valve is closed.
2.   Control  knob  not fully  pressed  in
      while  pressing  ignitor  button.
3.   Air  in  gas  lines  when  installed.
4.    ODS/pilot  is  clogged.
5.   Control  knob  not in  PILOT  position.
6.  Gas regulator setting  is  not  correct.
7.  Depleted  gas  supply.
1.   Control knob is not fully pressed in.
2.   Control  knob  is not  pressed  in
      long  enough.
3.   Equipment  shutoff  valve  is not
      fully open.
4.   Thermocouple   connection   is
      loose at  control  valve.
5    Pilot      flame    is  not    touching
      t herm oc ouple,     T his   allow s
      thermocouple  to cool,causing pilot
     flame  to  go  out. This  problem
      could  be  caused  by  one  or  both
      of  the  following:
      A)  Low gas pressure
      B)  Dirty    or  partially    clogged
           ODS/pilot
6.   Thermocouple   damaged.
7.   Control valve   damaged.
REMEDY
1.   Replace ignitor.
2.   Replace ignitor.
3.   Reconnect ignitor cable.
4.   Free  ignitor  cable  if  pinched  by
       any       metal     or     tubing.    Keep
      ignitor   cable  dry.
5.   Replace   ignitor  cable.
6.   Replace  piezo ignitor.
1.   Turn    on    gas    supply    or   open
      equipment  shutoff  valve.
2.  Fully   press   in   control   knob
      while  pressing  ignitor  button.
3.   Continue   holding    down    control
knob.  Repeat  igniting  operation
      until  air  is  removed.
4.   Clean  ODS/pilot (see Cleaning  and
      Maintenamce, Page 13)  or  replace
     ODS/pilot  assembly.
5. Turn control  knob to  PILOT  position.
6.  Replace  gas  regulator.
7. 
Contact local prapane/LP gas  company.
1.   Press in control knob fully.
2.   After  ODS/pilot lights, keep control
      knob  pressed  in  30  seconds.
3.    Fully  open equipment shutoff valve.
4.  Hand   tighten   until   snug,   then
      tighten 1/4  turn more.
5.   A)  Contact  local  propane/LP  gas
      company.
      B)    Clean   ODS/pilot (see  Cleaning
     and   Maintenance,  Page 13)   or
      replace  ODS/pilot  assembly.
6.   Replace   thermocouple.
7.  Contact Dealer or PRO-COM