Procom MN100HPA 用户手册

下载
页码 23
1 0
Figure 13-Equipment  Shutoff  Valve
INSTALLATION
CHECKING GAS
CONNECTIONS
   
WARNING: 
  
Test  all  gas piping
and  connections  for  leaks after
installing  or  servicing.   Correct   all
leaks   at   once.
   
WARNING:  Never  use  an  open
flame   to   check   for   a   leak. Apply
a   mixture  of   liquid   soap and
water   to  all   joints.  Bubbles  form-
ing show  a  leak.  Correct  all   leaks
at  once.
Pressure  Testing  Gas  Supply
Piping  System
Test  Pressures  In  Excess  Of
1/2  PSIG  (3.5 K Pa)
1.   Disconnect   appliance   with   its
       appliance       main        gas     valve
     (control valve)   and   equipment
      shutoff    valve   from   gas   supply
         piping    system.   Pressures   in
       excess  of   1/2  psig  will  damage
      heater  regulator.
2.    Cap   off  open   end   of   gas  pipe
where  equipment  shutoff  valve
       was   connected.
3.     Pressurize  supply  piping     sys-
tem  by  either using  compressed
air   or    opening
       main  gas  valve  located  on  or
near  gas  meter.
4.   Check  all  joints  of  gas  supply
piping  system.  Apply  mixture  of
liquid  soap  and  water  to  gas
joints.  Bubbles    forming    show
      a  leak.
5.   Correct  all  leaks  at  once.
6.   Reconnect heater and equipment
       shutoff  valve  to  gas supply.  Check
reconnected   fittings  for  leaks.
Test  Pressures  Equal  To or
Less  Than  1/2  PSIG  (3.5 K Pa)
1.   Close equipment  shutoff  valve
       (see Figure 13).
2.   Pressurize  supply  piping  system
       by  either  using  compressed  air
      or   opening    main    gas   valve
      located  on  or  near  gas  meter.
3.   Check  all  joints  from  gas  meter
      to  equipment  shutoff  valve  (see
      Figure   14).   Apply    mixture   of
       liquid  soap and water to  gas joints.
      Bubbles  forming show a leak.
4.   Correct  all  leaks  at  once.
Pressure  Testing  Heater  Gas
Connections
1.  Open  equipment  shutoff  valve
      (see  Figure  13).
2.   Open main  gas  valve  located  on
      or  near gas  meter.
3.   Make    sure    control    knob    of
      heater  is  in  the  OFF position.
4.   Check  all  joints  from  equipment
      shutoff   valve   to   control   valve
      (see  Figure 14 ).  Apply  mixture  of
      liquid   soap    and    water  to   gas
        joints.  Bubbles    forming    show
      a  leak.
5.   Correct all leaks at once.
6.  Light    heater    (see   Operating
      Heater,  pages  10,11  and  12)
     Check   the  rest  of  the   internal
      joints  for  leaks.
7.   Turn  off  heater (see  To  Turn  Off
      Gas  to  Appliance,  pages 11 and
12) .
8.   Replace  lower  front  panel.
OPERATING YOUR HEATER
n
FOR YOUR SAFETY
n
READ BEFORE LIGHTING
A.  When  lighting  the  pilot,  follow
      these  instructions  exactly.
B.  BEFORE  LIGHTING   smell  all
     around   the  appliance  area  for
     gas.  Be  sure  to  smell  next  to
      the  floor  because  some  gas  is
     heavier  than  air  and  will  settle
      on the  floor .
WHAT TO DO  IF YOU SMELL GAS
Do  not  try  to  light any  appliance.
Do not touch any electric switch;
        do  not  use  any  phone  in  your
       building.
Immediately       call      your     gas
        supplier  from    a    neighbor’s
       phone.     Follow        the        gas
       supplier’s   instructions.
If     you     cannot    reach     your
        gas    supplier,    call      the    fire
      department.
C.  Use  only  your  hand  to  push  in
     or  turn  the   gas   control  knob.
     Never   use   tools.  If   the   knob
       will    not    push    in   or    turn    by
      hand, don’t  try  to  repair  it, call
     a qualified service technician or
      gas supplier. Force or attempted
        repair  may  result  in    a  fire  or
      explosion.
D.  Do not use this appliance if any
      part  has   been  under  w ater.
        Immediately    call    a    qualified
     service  technician   to   inspect
      the  appliance   and   to   replace
      any  part  of  the  control  system
     and any  gas control which has
      been  under  water.
Figure 14 -Checking  Gas  Joints
            WARNING:   If  you  do  not
follow   these  instructions  exactly,
a   fire   or   explosion  may  result
in causing property damage
personal   injury or loss of  life.
WARING
:
Do not  over tighten gas
    connections.