United States Stove 5510 用户手册

下载
页码 24
USSC 
3
Safety Precautions
IMPORTANT: Read this entire manual before installing
and  operating  this  product.    Failure  to  do  so  may
result in property damage, bodily injury, or even death.
Proper installation of this stove is crucial for safe and
efficient operation.
Install  vent  at  clearances  specified  by  the  vent
manufacturer. 
Do not connect the pellet vent to a vent serving any
other appliance or stove.
Do  not  install  a  flue  damper  in  the  exhaust  venting
system of this unit.
Use of outside air is not required for this unit.
Contact  your  local  building  officials  to  obtain  a
permit and information on any additional installation
restrictions or inspection requirements in your area.
Do  not  throw  this  manual  away.   This  manual  has
important  operating  and  maintenance  instructions
that you will need at a later time. Always follow the
instructions in this manual.
This appliance is designed for the use of pelletized fuel
that meet or exceed the standard set by the Pellet Fuel
Institute (PFI). The use of other fules will void warranty.
Never  use  gasoline,  gasoline-type  lantern  fuel,
kerosene,  charcoal  lighter  fluid,  or  similar  liquids  to
start or ’freshen up’ a fire in this stove. Keep all such
liquids well away from the stove while it is in use.
A working smoke detector must be installed in the same
room as this product.
Do not unplug the stove if you suspect a malfunction.
Turn the ON/OFF SWITCH to ”OFF’ and contact your
dealer.
Your stove requires periodic maintenance and cleaning
(see ”MAINTENANCE ”). Failure to maintain your stove
may lead to improper and/or unsafe operation.
Disconnect  the  power  cord  before  performing  any
maintenance! NOTE: Turning the ON/OFF Switch to
”OFF” does not disconnect all power to the electrical
components of the stove.
Never try to repair or replace any part of the stove un-
less instructions for doing so are given in this manual.
All other work should be done by a trained technician.
Do  not  operate  your  stove  with  the  viewing  door
open.   The  auger  will  not  feed  pellets  under  these
circumstances and a safety concern may arise from
sparks or fumes entering the room.
 
 
 
 
 
 
Allow  the  stove  to  cool  before  performing  any
maintenance or cleaning. Ashes must be disposed
in a metal container with a tight fitting lid. The closed
container  of  ashes  should  be  placed  on  a  non-
combustible surface or on the ground, well away from
all combustible materials, pending final disposal.
The exhaust system should be checked monthly during
the burning season for any build-up of soot or creosote.
Do not touch the hot surfaces of the stove. Educate all
children on the dangers of a high-temperature stove.
Young children should be supervised when they are
in the same room as the stove.
The hopper and stove top will be hot during operation;
therefore, you should always use some type of hand
protection when refueling your stove.
A power surge protector is required. This unit must
be  plugged  into  a  110  -  120V,  60  Hz  grounded
electrical outlet. Do not use an adapter plug or sever
the grounding plug. Do not route the electrical cord
underneath,  in  front  of,  or  over  the  heater.    Do  not
route the cord in foot traffic areas or pinch the cord
under furniture.
The heater will not operate during a power outage. If a
power outage does occur, check the heater for smoke
spillage and open a window if any smoke spills into
the room.
The  feed  door  must  be  closed  and  sealed  during
operation.
Never  block  free  airflow  through  the  open  vents  of
the unit.
Keep foreign objects out of the hopper.
The moving parts of this stove are propelled by high
torque electric motors. Keep all body parts away from
the auger while the stove is plugged into an electrical
outlet. These moving parts may begin to move at any
time while the stove is plugged in.
Do not place clothing or other flammable items on or
near this stove.
When  installed  in  a  mobile  home,  the  stove  must
be grounded directly to the steel chassis and bolted
to  the  floor.    WARNING—THIS  UNIT  MUST  NOT
BE  INSTALLED  IN  THE  BEDROOM  (per  HUD
requirements).    CAUTION—THE  STRUCTURAL
INTEGRITY OF THE MOBILE HOME FLOOR, WALL,
AND CEILING/ROOF MUST BE MAINTAINED.  
This appliance is not intended for commercial use.
 
 
 
 
* This appliance is a freestanding heater. It is not intended to be attached to any type of ducting. It is not a furnace.