Trane TUD2C080A9V4VB 用户手册

下载
页码 26
2
22-1650-13
General
Features
© 2011  Trane
NATURAL GAS MODELS
Central Heating furnace designs are cer-
tified by the American Gas Association 
for both natural and L.P. gas.  Limit setting 
and rating data were established and 
approved under standart rating condi-
tions using American National Standards 
Instirute standards.
SAFE OPERATION
The Integrated System Control has solid 
state devices, which continuously monitor 
for presence of flame, when the system 
is in the heaating mode of operation.  
Dual solenoid combination gas valve and 
regulator provide extra safety.
QUICK HEATING
Durable, cycle tested, heavy gauge 
aluminized steel heat exchanger quickly 
transfers heat to provide warm condi-
tioned air to the structure.  Low energy 
power vent blower, to increase efficiency 
and provide a positive discharge of gas 
fumes to the outside.
BURNERS
Multiport In-shot burners will give years 
of quiet and efficient service.  All models 
can be converted to L.P. gas.
INTEGRATED SYSTEM CONTROL
Exclusively designed operational program 
provides total control of furnace limit 
sensors, blowers, gas valve, flame control 
and includes self diagnostics for ease of 
service.  Also contains connection points 
for E.A.C./humidifier.
AIR DELIVERY
The variable speed, direct drive blower 
motor, has sufficient airflow for most 
heating and cooling requirements, will 
switch from heating to cooling speeds 
on demand from room thermostat.  The 
blower door safety switch will prevent or 
terminate furnace operation when the 
blower door is removed.  Some models 
are available with high efficiency blowers.
STYLING
Heavy gauge steel and “wrap-around” 
cabinet construction is used in the 
cabinet with baked-on enamel finish for 
strength and beauty.  The heat exchanger 
section of the cabinet is completely 
lined with foil faced fiberglass insulation.  
This results in quiet and efficient opera-
tion due to the excellent acoustical and 
insulating qualities of fiberglass.  Built-in 
bottom pan and alternate bottom, left or 
right side return air connection provision.
FEATURES AND GENERAL OPERA-
TION
The XV80 High Efficiency Gas Furnaces 
employ a Hot Surface Ignition system, 
which eliminates the waste of a constant 
burning pilot.  The integrated system 
control lights the main burners upon a de-
mand for heat from the room thermostat.  
Complete front service access.
    a.  Low energy power venter
    b.  Vent proving pressure switch.