REFERENCE LETTER TO 
DRAWING 
CANADIAN INSTALLAT
A = Clearance above grade,  veranda, 
porch, deck, or balcony 
12 Inches (30 cm) 
B = Clearance to window or door that 
may be opened 
12 Inches (30 cm) 
C = Clearance to permanently closed 
window 
12 Inches (30 cm) 
D = Vertical clearance to ventilated 
soffit located above the terminal within 
a horizontal distance of 2 Feet (61 cm) 
from the center line of the terminal 
18 Inches (46 cm) 
E = Clearance to unventilated soffit 
24 Inches (61 cm) 
F = Clearance to outside corner 
12 Inches (30 cm) 
G = Clearance to inside corner 
12 Inches (30 cm) 
H = Clearance to each side of center 
line extended above meter/ regulator 
assembly 
3 Feet (91 cm) within a height 
15 Feet (4.5m) above the meter/
assembly 
I = Clearance to service regulator  vent 
outlet 
3 Feet (91 cm) 
J = Clearance to nonmechanical air 
supply inlet to building or the 
combustion air inlet to any other  
appliance 
12 Inches (30 cm) 
K = Clearance to a mechanical air 
supply inlet 
6 Feet (1.83 m) 
L = Clearance above paved sidewalk  or 
paved driveway located on public 
property 
7 Feet (2.13m)  A vent shall not te
directly above a sidewalk or pav
driveway that is located betwee
single family dwellings and serve
dwellings. 
M = Clearance under veranda,  porch, 
deck, or balcony 
12 Inches (30 cm) permitted only
veranda, porch, deck, or balcon
open on a minimum of two sides
¹ In accordance with the current CSA-B149.1 Natural Gas and Propa
Vent Terminal
Air Supply Inlet
Area where terminal is not permitted
VENT TERMINAL CLEARANCES