Hitachi NT50AGF 用户手册

下载
页码 102
— 14 —
English
AIR SUPPLY
 
DANGER
• 
NEVER use oxygen or other bottled 
      gases. Explosion may occur.
 
WARNING
• 
Never connect Nailer to pressure which potentially exceeds  
200 psi (13.7 bar      14 kgf/cm2).
• 
Never use non relieving coupler on Nailer.
1. Power Source
V
  Use only clean, dry, regulated compressed air as a power source 
for this Nailer
V
  Air compressors used to supply compressed air to this Nailer 
must comply with the requirements of the latest version of ANSI 
Standard B 19.3 “Safety Standard For Compressors For Process 
Industries.”
V
  Moisture or oil in the air compressor may accelerate wear and 
corrosion in the Nailer.
V
  Drain daily.
V
  Air volume is as important as air pressure. Both should be con-
sidered when choosing a compressor to use with this tool. The 
air volume supplied to the tool may be inadequate because of 
undersized fittings and hoses or from the effects of dirt and wa-
ter in the system. Inadequate or restricted air flow will prevent 
the tool from receiving an adequate volume of air, even though 
the pressure reading is high. Compressors with lower CFM rat-
ings may experience inadequate air flow while the compressor 
is running. Low volume or pressure may result in slow opera-
tion, jamming, miss-feeds or reduced driving power.
V
  Air Compressor:
  Minimum Air Compressor Requirements
 • HP: 1 1/2 HP or greater.
 • Compressor Rated at 135 PSI Max. or greater.
 • Accumulator Tank Capacity: 4 Gallons or greater
 • Pressure Regulator: Set operating pressure at 90 - 110 PSI.
 • SCFM @ 90 PSI: 3.5 CFM
 • Pressure Switch Trip On: 110 PSI (± 5)