1. Resetting the Piston / Driver Blade
Disconnect from the Air source.
Unload all of the fasteners from the magazine.
Make sure there are no fasteners in the guide chamber.
Reconnect the air source to the Tool.
While squeezing the safety lever, push the ram down and hold 
for three (3) seconds and release.
Load fasteners and proceed with the operation of the Tool.
2. Inspecting the Magazine
o
 
DISCONNECT THE AIR HOSE
o
 
Clean the magazine. Remove dust or wooden tips which may 
have accumulated in the magazine.
3. Storing
o
 
When not in use for an extended period, apply a thin coat of the 
lubricant to the steel parts to avoid rust.
o
 
Do not store the Tool in a cold weather environment. When not 
in use, the Tool should be stored in a warm and dry place.
o
 
Keep out of reach of children.