Allstar Products Group MVP-SB 用户手册

下载
页码 20
TURNING ON POWER TO THE 
OPENER 
 
NOTE:  It is now necessary to turn on the 
power in order to run the opener to test the 
operation and check the limit settings.  Before 
doing so, ensure that all mounting hardware is 
installed and has been properly tightened, that 
all electrical connections are per local code 
requirements, and that proper wiring practices 
have been followed.  Also, double-check that 
all ropes have been removed from the door 
and that the doorway is clear.  
 
BASIC OPERATING PARAMETERS 
 
Please note the following Operating Parameters which 
apply to openers with Auxiliary Entrapment Protection 
System (Safe Finish™ Photosystem, Installation 
Instructions on Page 10) and a standard wall push 
button connected.  Please see page 17 for instructions 
concerning the Super Station Deluxe Wall Push Button 
operating parameters. 
 
IF THE DOOR IS… 
...FULLY OPEN,
 then pushing the standard wall Push 
Button or the radio control will cause the door to begin 
MOVING DOWNWARD. 
...FULLY CLOSED,
 then pushing the wall Push 
Button or the radio control will cause the door to begin 
MOVING UPWARD. 
...MOVING UPWARD, then pushing the wall Push 
Button will cause the door to STOP.  The  next push of 
the wall button will cause the door to begin MOVING 
DOWNWARD (Alternate Action Operation).
 
...MOVING UPWARD, then pushing the radio control 
will cause the door to STOP.  The  next push of the 
wall button will cause the door to RESUME 
UPWARD  MOVEMENT (Radio Operation).
 
...MOVING DOWNWARD, then pushing the wall 
Push Button or the radio control will cause the door to 
STOP, PAUSE FOR APPROXIMATELY ONE 
SECOND, AND THEN BEGIN MOVING 
UPWARD.  
...MOVING DOWNWARD
 then reaches the down 
limit, the lamp will blink off for a 1/2 second then turn 
back on again, remaining on for 4 minutes 30 seconds 
and will then automatically turn off. 
...MOVING UPWARD then reaches the open limit, 
the lamp will remain on for 4 minutes 30 seconds and 
will then automatically turn off. 
At this time (before connecting the door arm) activate 
the door operator through 2 cycles of operation to 
verify proper limit function.  The trolley should stop at 
a minimum of 2 inches before its front edge encounters 
the Stop Bolt on the rail (Closed Position) and a 
minimum of 4 inches before its back edge encounters 
the Stop Bolt on the opposite end of the rail (Open 
Position).  Leave the trolley at the Closed Position on 
the rail. 
12 
PRE-POWER ON- 
 INSTALLATION CHECKLIST 
Before continuing with the operation and 
adjustment section, make sure that

 
1. The front and rear mounts for the operator are 
sound and secure and the rail is positioned 
correctly above the high arc of the door, and that 
the opener is positioned over the door action 
centerline. 
2. The Manual Release Label and cord are secure 
to the Manual Release Lever and the handle is 
located 6 FT above floor level.  The trolley and 
the release mechanism have been lubricated with 
a silicone spray.  
3. The standard wall push button or the Super 
Station (deluxe wall push button station) is in 
such a position and of such a height that it can 
only be actuated by an adult of average height.  
The Control Button Warning label is 
prominently displayed next to the push button or 
wall station.  
5. All wiring is correct to codes or better.   There is 
ground continuity from the supply.  The ground 
prong on the power cord is intact.  
6. All ropes have been removed from the door.  
The door moves freely without binding when 
raised or lowered manually.  The door is 
correctly balanced and lubricated.  All door 
hardware is secure and sound.  The sensitivity 
has been adjusted to minimum force for the 
application. 
7. The plastic envelope for this manual is attached 
to the wall near the push button or wall station 
and this manual is placed there for owner use 
and reference.   
9. On door with extension type counterbalance 
springs, restraint cables have been placed 
through the springs. 
10. On doors with adjustable bottom edges, edges 
have been locked after adjustment. 
OPERATION AND ADJUSTMENT INSTRUCTIONS