STEP 1:  
Testing the Limit Settings: To check the 
Limit Settings, start the Opener by pushing the standard 
wall Push Button or Super Station.  Be prepared to 
activate the button again quickly - per the Operating 
Parameters outlined on page 12 - or if you see that the 
door is going to over travel.  As illustrated below, move 
the Cams toward the Power Unit to DECREASE door 
travel and toward the Front Idler to INCREASE door 
travel.  Adjust the Up Limit Cam so that the door 
comes to rest where it normally would without an 
electric Opener. Adjust the Down Limit Cam so that 
the door closes firmly without putting undue stress on 
the Door Arm.  At full closed position, the door arm 
assembly should compress approximately one inch. 
STEP 2:  
Adjusting the Sensitivity Force — 
Sensitivity System force adjustment screws are located 
on the side rails of the Power Unit and can easily be 
adjusted with a screwdriver.  Turn the screws 
CLOCKWISE for more force and 
COUNTERCLOCKWISE for less force.  
    
STEP 3: 
Testing the Sensitivity Force — To test 
the Sensitivity System, start the Opener and grasp the 
bottom door handle halfway through the door's travel 
(opening or closing). 
  As an 
alternate, 
use a stiff 
cardboard 
carton 
placed in 
the door's 
downward 
path to 
indicate the force the Opener is exerting. 
If the force adjustment screws are properly set, the door 
should stop if opening, and reverse if closing without 
exerting undue pressure. 
 
 
 
 
 
 
 
STEP 4: 
 
Testing the Opener’s Reversing System 
 To test the Opener's Reversing Feature at floor level, 
place a solid object 1-1/2" thick (such as a standard 2 X 
4 board laid flat) on the ground where the center of the 
door will contact it.  Close the door. If the down force 
 
OPEN FORCE  
ADJUSTMENT 
CLOSE FORCE 
ADJUSTMENT 
104391 
OPERATION AND ADJUSTMENT INSTRUCTIONS 
108407 
WARNING 
              
W A R N I N G
 
IMPROPER ADJUSTMENT OF 
SENSITIVITY SYSTEM FORCE COULD 
CAUSE ENTRAPMENT, INJURY OR 
DEATH.  SET ADJUSTMENTS FOR JUST 
ENOUGH FORCE TO OPERATE THE 
DOOR RELIABLY, BUT NO STRONGER.  
Contact a service professional to 
correct any binding, sticking or other 
door problems.  DO NOT OVER-ADJUST 
SENSITIVITY SYSTEM TO 
COMPENSATE FOR A POORLY 
WORKING DOOR. 
THE SENSITIVITY SYSTEM REVERSING TEST 
SHOULD BE PERFORMED MONTHLY TO 
ENSURE THAT THIS IMPORTANT SYSTEM 
REMAINS IN PROPER ADJUSTMENT. 
 
       